3.2.
Consumption values
Table 1_ Consumption values (for Remay burners)
LPG G30 - 30 mbar
Injector
Power
(mm)
(kW)
Small
Ø0,50
1,00
Burner
Medium
Ø0,72
2,00
Burner
Big Burner
Ø0,85
2,90
Wok
Burner
Ø0,98
3,80
(Defendi)
Table 1.1_ Consumption values (for Sabaf burners)
LPG G30 30 mbar
Injector
Power
(mm)
(kW)
Small
Ø0,50
1,00
Burner
Medium
Ø0,70
2,00
Burner
Big Burner
Ø0,85
2,90
Fish
Ø0,68
1,80
Burner
Mini Wok
Ø0,82
2,50
Wok
Burner
Ø1,00
3,80
(3.8 kW)
Wok
Burner
Ø1,03
4,20
(4.2 kW)
The firm may make change in the technical specifications to
improve quality of the product without prior notice.
The figures given in the manual are schematic and may not be
exactly same with your product.
The values given on the markings on the product or in the other
printed documents provided with the product are values obtained under
the laboratory conditions as per the applicable standards. These values may
vary depending on the use and ambient conditions of the product.
NG G20 - 20 mbar
Consum
Injector
Power
ption
(mm)
(kW)
(g/h)
73
Ø0,70
1,00
145
Ø1,03
2,00
211
Ø1,24
2,90
276
Ø1,45
3,80
NG G20 20 mbar
Consum
Injector
Power
ption
(mm)
(kW)
(g/h)
73
Ø0,72
1,00
145
Ø1,03
2,00
211
Ø1,15
2,90
131
Ø0,94
1,80
182
Ø1,15
2,50
276
Ø1,50
3,80
305
Ø1,50
4,20
LPG G30 - 50 mbar
Consump
Injector
Powe
tion
(mm)
r (kW)
(m3/h)
0,095
Ø0,43
1,00
0,190
Ø0,62
2,00
0,276
Ø0,75
2,90
0,362
Ø0,98
4,70
LPG G30 50 mbar
Consump
Injector
Powe
tion
(mm)
r (kW)
(m3/h)
0,095
Ø0,43
1,00
0,190
Ø0,62
2,00
0,276
Ø0,75
2,90
0,171
Ø0,59
1,80
0,238
Ø0,73
2,50
0,362
Ø0,78
3,80
0,400
Ø0,83
4,20
NG G25.3 - 25 mbar
Consu
Injector
Power
mption
(mm)
(kW)
(g/h)
73
Ø0,75
1,00
145
Ø1,06
2,00
211
Ø1,27
2,90
342
Ø1,40
3,80
NG G25.3 25 mbar
Consu
Injector
Power
mption
(mm)
(kW)
(g/h)
73
Ø0,75
1,00
145
Ø0,97
2,00
211
Ø1,18
2,90
131
Ø0,98
1,80
182
Ø1,15
2,30
276
Ø1,45
3,80
334
Ø1,50
4,20
EN
Consu
mption
(m3/h)
0,111
0,221
0,321
0,421
Consu
mption
(m3/h)
0,111
0,221
0,321
0,199
0,255
0,421
0,465
15