WiNteriZiNG

proper procedures should always be taken in order to protect your filter in cold climates
(temperatures below freezing point).
1. Switch off the pump / Close the inlet valve.
2. Open the air release valve and open the purge valve to allow water to flow out of the
MultiCyclone.
a. Sand filter, move the Multi port Valve handle to the winterise position
(between filter and waste).
b. Cartridge filter, open air release valve. This will allow air to through to all ports.
3. Remove any drain plugs from the pump.
4. drain water from the pipe work.

trOUBLeshOOtiNG GUiDe

symptoms
Possible Problems / solutions
Insufficient disinfectant level.
Incorrect pool chemistry.
Heavy bathing and/ or dirt loads.
Incorrect flow.
Insufficient running times. (Increase pump run time.)
filter is dirty. (Clean per instructions.)
Water Is not Clear
Hole in filter element.
air leak on suction line
pump impeller vanes blocked
Other restrictions include (pool suction cleaners) resistance from other inline
equipment such as strainers.
pump not primed.
Check strainer baskets for debris.
Check for air leaks on suction side.
Check for restrictions or blockage in either suction or return lines.
System filter needs to be cleaned or replaced.
Low Water flow
pool water level too low.
pump not primed.
pump impeller vanes blocked.
Strainer baskets not being used and/ or not being cleaned regularly.
pump operating under speed (low voltage).
presence of algae, check disinfectant content.
Check pH and total alkalinity.
Short filter Cycles
Pump output exceeds design flow rate of filter, check pump performance.
Ineffective cleaning, check conditionsof sediment chamber.
Small eyeball fitting in pool/ Spa.
High pressure on
partially closed valve on return line.
Start Up
Too large of pump, check selection.

WArrANtY

MultiCyclone is covered by a 2 year warranty. Commercial installations are covered by a 1 year
warranty.