Equipment designed for operating rolling shutters, with limit switches integrated on motor. Up to a maximum power of 736 W.
Receiver integrated on control panel for 433 or 868 Mhz transmitters (depending on version).
2. OPERATION
Protected inputs for operations. Protection of main feed and motor with fuse 6A and Varistore. Power-ON led. START button and Safety contact inputs.
You could start an operation with an emitter or with START button.
The operation Ends due to the follow conditions: activation of door limit switches or by the end of operation time.The maneuver time is programmable by
PROG.button. The default time is 30 seconds without automatic closing.
The equipment allows the programming of closing time. (see point 6.)
Emitter and the START button activate the same function. If the door is in an opening operation and we push the emitter or START button the door stops, if we
push another time the door starts a closing operation, if we push another time the door starts an opening operation, and successively. (OPEN - STOP - CLOSE -
STOP - OPEN)
3. TERMINAL CONNECTIONS
4. OPTIONS SELECTOR
DEAD MAN
(HOMBRE PRESENTE)
RADIO
PROGRAMMING
(PROG. RADIO)
5. TRANSMITTER PROGRAMMING
1.5s
PROG.
1 X
PUSH
BEEP
PROG. ON
CONTROL PANEL
SIMPLY
SIMPLY Instructions
HOMBRE PRESENTE
PROG. RADIO
ON
ON
- For closing operation you must press continually the START button or the
Emitter. If you do not press the button the door stops.