Osmofilter TM68 Manual De Usuario página 46

Ocultar thumbs Ver también para TM68:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Select the desired option using the UP and DOWN keys and press the "MENU" key to confirm.
Button "MENU"
5. Setting the regeneration time:
This option is only editable if you have chosen a type of regeneration delayed in point 3 (A-01, A-03). Press
the DOWN key again to display the regeneration time.
Modify the time by pressing the "menu / confirmation" key, and then adjust it with the UP and DOWN keys.
Normally it will be left at 2:00 in the morning, which is the time at which it is preset. Press "menu / confirma-
tion" to confirm.
6. Set the water volume to be treated:
Press the button DOWN. The screen will show the program 1, wich corresponds to the backwash interval,
that is, the number of regenerations in which the valve does not make a backwash. For up flow valves is not
necessary to perform a backwash in each regeneration. To adjust, press "Menu/confirm" and change the
value with UP and DOWN until the desired value. Press "Menu/confirm" to confirm.
7. Volume-to-treat settings:
Configuration for volume of water to be treated in m
volume that can be decalcified, according to table 1.
Press the DOWN key. The display will show the amount of water in m3 that will pass through the resin after
the regeneration process. Press the "menu / confirmation" key again and the value will start blinking. You
can change this amount using the UP and DOWN buttons. Press "menu / confirmation" to confirm and move
to decimal setting. Modify the quantity with the "UP" / "DOWN" buttons.
Button "UP"
Button "DOWN"
Button "MENU"
Button "UP"
Button "MENU"
, (options A-01, A-02, section 3). We will mark the
3
Button "MENU"
Button "DOWN"
Button "MENU"