note: Keep your receipt and these instructions for proof of purchase.
WARninG: Shut off the power at the circuit breaker or fuse panel before removing the old fixture, ballast, or fluorescent tubes.
If you are unfamiliar with electrical installations, we recommend you contact a qualified electrician to do the installation.
Package contents
Part Description
A
Fixture
B
TwistFit Mounting Plate
C
Wire Connector
D
Screw
InstaLLatIon
Select a suitable location that can support the weight of the fixture. Determine the method of mounting before drilling.
WARninG: RISK OF ELECTRIC SHOCK. Ensure the electricity to the wires you are working on is shut off. Either remove the fuse or turn off the circuit breaker before removing the
existing light fixture or installing the new one. With power disconnected to your electrical box, remove the existing fixture. Make a sketch of how the current fixture is wired (by wire color) or
mark the wires with masking tape and a pencil so you will know how to properly reconnect the wires to the new LED light fixture.
RISK OF ELECTRIC SHOCK - These servicing instructions are for use by qualified personnel only. To reduce the risk of electric shock, do not
perform any servicing other than that contained in the operating instructions unless you are qualified to do so.
This product complies with the maximum allowable concentration of ozone of 0.050 parts per million by volume (ppmv) in a 24-h period.
B
D
2.75"(70mm)
3.54"(90mm)
1
Pass the power input line through the
middle hole of the TwistFit mounting plate
(B), and fix the mounting plate (B) on the
junction box with the screw (D).
4
Position the wires back inside the junction
box. Lift the flush mount and secure it
onto the TwistFit mounting plate by turning
clockwise to tighten it.
WARninG: Carefully read and understand the information given in this manual before beginning the assembly and installation. Failure to do so could lead to electric shock, fire, or
other injuries which could be hazardous or even fatal. • Ensure the electricity to the wires you are working on is shut off. Either remove the fuse or turn off the circuit breaker. • SUITABLE
FOR OPERATION IN AMBIENT NOT EXCEEDING 45°C. SUITABLE FOR DAMP LOCATIONS. MINIMUM 90°C SUPPLY CONDUCTORS. CAUTION-RISK OF SHOCK. DISCONNECT POWER BEFORE
SERVICING.
notiCe: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired operation. These limits are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio
or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna, increase the separation between the equipment and the receiver, connect the equipment into an outlet on a circuit different from that to which
the receiver is connected, and consult the dealer or an experienced radio/TV.
• Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
See website for Warranty, Troubleshooting or Care and Cleaning details at www.ETiSSL.com.
TM
USe AnD CARe GUiDe
LeD PLASMA FLUSH MoUnt
Quantity
1
1
2
2
2700K 3000K 3500K 4000K 5000K
2
Remove the lamp shade counterclockwise and adjust the
middle color temperature switch to the desired position.
The default value is 2700K, then install the lampshade.
5
Fixture has two working modes controlled by the wall switch.
When the switch is turned on for the first time, it is the first
mode: the lighting and disinfection function are on together, the
fan speed is low and the noise is low. When the wall switch is
turned off and the switch is turned on again within 3 seconds,
it enters the second sterilization mode without lighting. At this
time, the fan is at high speed with efficient sterilization.
Questions, problems, missing parts? Call ETiSSL Customer Service 8 a.m. - 5 p.m., CST, Monday - Friday
1-855-etI-ssLI (1-855-384-7754) www.etissL.com
Part # SAFM-R12-PL-1000LM-9-CP5-MV-D-WH
A
B
A
3
a. Connect the black wire from the fixture body to the
black wire from the junction box.
b. Connect the white wire from the fixture body to the
white wire from the junction box.
6
Clean the dust covers when noticing a decreased air
volume. Remove the dust covers on both sides, clean the
dust off the net, and then install it as it is.
Model # 559031110
C
D
B
C
C