EGAmaster 62955 Manual De Instrucciones página 20

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

7. COMMUNICATION
PRECAUTION:
1.Communication function is only supported on some models ( code: 62959-62962).
2. Do not insert the plug of communication cable into torque wrench that does not support com-
munication function.
CONNECTING COMMUNICATION CABLE
Turn off power and then connect the accesory cable between the RS232 COM port of PC and
torque wrench.
UPLOADING RECORD DATA
Make sure the connection between PC and wrench is normal..
Press
together to reset the wrench.
Change the wrench operation mode to
. (Please refer to "Peak Hold Mode Recorded Value
Review" section)
Use PC to start the uploader program.
In uploader program, first select the correct COM port No.
Next, select the file path to save the uploaded data.
Finally, press "upload" button to transmit the torque records to PC.
The uploaded data is then shown on the column and saved in the *.csv file. Use Microsoft Exce to
view *.csv file.
20

Publicidad

Tabla de contenido
loading

Tabla de contenido