5.2.2
DOSE DISPENSING AND ADJUSTMENT
• After positioning the filter-holder on the fork, choose the dose to be dispensed by
pressing the single dose (14)
button lights up).
• During dispensing, the display will show the value of the weight measured up to the
set value.
• During dispensing, the single (or double) dose button flashes.
ATTENTION
The selected dose key remains enabled for 10 seconds from the positioning of
the filter-holder. After 10 seconds, when the key is pressed, the machine stops
and the abbreviation FH appears on the display. To release the grind, remove the
filter-holder and reinsert it.
ATTENTION
If the filter holder is not inserted correctly, pressing the key does not start
grinding and the abbreciation FH appears on the display. To release the grind,
remove the filter-holder and reinsert it.
ATTENTION
Grinding should only start after inserting the filter-holder or another container on
the filter-holder fork.
• When dispensing is finished, the grinding grams of the dose return to the set value
and the counter is increased by the value of the ground grams.
• Press the buttons (12)
required for the selected dose (weight visible in grams on the display). The increase
or decrease in grams provided for the selected dose varies to a tenth of a gram.
• If the button (12)
weight of the selected dose is decreased or increased for the time of pressing.
To pause dispensing before the grinding time has elapsed, press one of
the two dose buttons again. The display shows the grams ground up to the
pause. To complete the dose it is necessary to press the dose button again.