INDICATORS
Large (.375") 3-character digital display in the upper left of the control panel indicates
many conditions and/or status codes:
When AC power is applied to the charger, actual charge rate in amps, when the battery is
fully charged, battery voltage, fault codes, operating modes and when the charger is ready
for the next mode selection. "Status Codes" are described below (FIGURE 5) and on the
back of charger.
AC POWER INDICATOR –
indicate power is on. Disconnect charger after use.

FAULT CODES

F01
INTERNAL SHORTED CELL BATTERY – Cannot be charged, bad battery. Replace battery.
EXCESSIVE LOAD ON BATTERY WHILE CHARGING – Check load.
F02
BAD BATTERY CONNECTION – Check battery connection.
BATTERY VOLTAGE TOO LOW TO ACCEPT CHARGE – Have battery checked.
F03
INTERNAL OPEN CELL – Bad battery. Battery needs to be replaced.
SULFATED CONDITION – Battery needs to be reconditioned. See manual.
F04
OVERTIME CONDITION – Battery will not accept a charge after 18 hours of continuoous charging. Battery ha internal damage
and needs to be replaced or BATTERY CHARGE RATE IS SET TOO LOW. Set charger to higher charge rate. See manual.
F05
OVERHEATED CONDITION – Disconnect charger and allow to cool for 30 min., check for ample ventilation.
F06
REVERSE POLARITY
F07
ALTERNATOR OUTPUT IS OUT OF TYPICAL OPERATION RANGE
OPERATION CODES
– – –
BATTERY RECONDITIONING – The letters DES will display for the first 3 seconds)
– – –
– – –
– – –
ALTERNATOR VOLTAGE CHECK
000
CHARGER STANDBY
FUL
BATTERY FULLY CHARGED
Below the digital display are a series of six LEDs that light on the following condi-
tions:
WET – Lights when battery type selector is on WET battery type.
GEL – Lights when battery type selector is on GEL battery type.
AGM – Lights when battery type selector is on AGM battery type.
Float Charge – Lights when automatic charge monitoring is active. This feature allows a
battery to maintain its charge over long periods of non-use. If there is any loss of power
to the charger once power is restored, charger will automatically return to the default set-
tings. Battery selector type would be "gel."
Battery Voltage – Lights when battery voltage is displayed.
Alternator Good – Lights when load or not load checks show the alternator is keeping
up with the electrical load.
Equalize – A recessed button used to start the equalize process.

CHARGE RATE SELECTION

After charger clamps are correctly connected, plug in the charger to an AC outlet and the
charger will show a circulating pattern on the digital display. This pattern indicates power
is applied. Select proper charge current rate based on battery size. Press the 2/10/25
amp push button and the charger will begin charging at 2 amps. Pressing the 2/10/25
amp push button again will advance the charge rate to 10A, then 25A. Pressing the
switch again will turn OFF the charger output and the display will show "000".
When connected to an AC outlet, digital display shows circulating pattern to
– 7 –