POWER CONTROL (1)

The power control is used for switching on and off and for setting the heating steps.
The following operating states can be set by turning the power control knob.
Device is switched off
Fan is on, heater is switched off (140 watts)
Fan and heater (7500 watts) are switched on
Fan and heater (15000 watts) are switched on

THERMOSTAT CONTROL (5)

The thermostat is used to switch off automatically when a preselected temperature is reached and
to switch on again automatically when the room temperature drops.
Turning the thermostat in the "plus" direction causes the
heating to switch off automatically when the temperature is
higher.
Turning the thermostat in the "minus" direction causes the
heating to switch off automatically when the temperature is
lower.
USE
1. Before use, check whether all parts are complete and in good condition
2. Remove the product from the carton and bag and make sure the unit is in the OFF position
before plug it into a power outlet.
3. Before using the heater, make sure the heater is on a flat and stable surface.
4. Use a three-phase power cord to connect the heater with standard AC three-phase power outlet.
Check whether the heater is connected to 400V 3~, the power supply for this heater is above
32A.
5. Firstly, to adjust the thermostat control knob (5) clockwise to the maximum, and then turn the
power control knob (1) clockwise to the cold air position
6. After the cold air is delivered normally, turning the power control knob clockwise as needed.
When it is turned to , the machine will heat with low-grade power; when it is turned to , the
machine will work with high-grade power. At this time, the warm air is quickly sent out, and the
heater is running normally.
7. If you want to maintain the current indoor temperature, you can slowly rotate the thermostat
control knob counterclockwise. When you hear a "click" sound, the heater stops working, and the
temperature control setting is completed. When the heater detects that the temperature is lower
than the set temperature, the heater will start working automatically.
8. Please cut off the power supply and unplug the plug when not in use or people go out.
BGS technic KG