SAFETY INSTRUCTIONS
Specifications
Double Float Tether Length Measurements
The double float pumping range is adjustable from 1.75 to 48 inches. The tether lengths are typically 3.5
inches.
SAFETY INSTRUCTIONS
This equipment should be installed and serviced by technically qualified personnel who are familiar with
the correct selection and use of appropriate tools, equipment, and procedures. Failure to comply with
national and local electrical and plumbing codes and within Little Giant recommendations may result in
electrical shock or fire hazard, unsatisfactory performance, or equipment failure.
Know the product's application, limitations, and potential hazards. Read and follow instructions carefully to
avoid injury and property damage. Do not disassemble or repair unit unless described in this manual.
Refer to product data plate(s) for additional precautions, operating instructions, and specifications.
Failure to follow installation or operation procedures and all applicable codes may result in the following
hazards:
Risk of death, personal injury, or property damage due to explosion,
fire, or electric shock.
• Do not use in flammable, combustible, or explosive fluids such as gasoline, fuel oil, kerosene, etc.
• Do not use in explosive atmospheres or hazardous locations as classified by the NEC, ANSI/NFPA70.
• Do not handle a switch or pump or pump motor with wet hands, or when standing on a wet or damp surface, or
in water.
• When a pump is in its application, do not touch the motor, pipes, or water until the unit is unplugged or electri-
cally disconnected.
• If the power disconnect is out of sight, lock it in the open position and tag it to prevent unexpected application of
power.
• If the disconnect panel is not accessible, contact the electric company to stop service.
High voltages capable of causing severe injury or death by electrical
shock are present in this unit.
• To reduce risk of electrical shock, disconnect power before working on or around the system. More than one dis-
connect switch may be required to de-energize the equipment before servicing.
• Some products are supplied with a grounding conductor and grounding-type attachment plug. To reduce risk of
electric shock, be certain that they are connected only to a properly grounded grounding-type receptacle. Do not
remove the third prong from the plug. The third prong is to ground the pump and switch to help prevent possible
electric shock hazard. Do not use an extension cord.
• Check electrical outlets with a circuit analyzer to ensure power, neutral, and ground wires are properly con-
nected. If not, a qualified, licensed electrician should correct the problem.
• Wire switch and pump system for correct voltages.
• The flexible jacketed cord assembly mounted to the switch must not be modified in any way, with the exception
of shortening the cord to fit into a control panel. Any splice between the switch and the control panel must be
made within a junction box mounted outside of the basin and comply with the National Electrical Code. Employ a
licensed electrician.
• Check local electrical and building codes before installation. The installation must be in accordance with their
regulations as well as the most recent National Electrical Code (NEC).
• Do not remove the third prong from the plug, or cut plug from cord. These actions will void the warranty.
2