En: Installation Sheet - Aritech ATS1235 Hoja De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 8

EN: Installation Sheet

Introduction
The ATS1235 Advanced Wireless DGP on 868 MHz AM
expands the ATS control panel's inputs using the Learn Mode
868 MHz AM Wireless Transmitter Sensors (crystal or SAW).
The maximum recommended data bus length is 1500 m when
one or more ATS1235 wireless DGPs are connected.
The ATS1235 can be powered by the control panel, or by
a remote, 220 V powered DGP.
Installation
ATS1235 PCBs layout
Figure 1
1)
Interface board.
(2) Radio board.
(3) External tamper connection. Place jumper when mounted in
plastic ATS control panel housing. Do not place jumper when
mounted in ATS1235 housing.
(4) USB connection (mini B-type). Used to upgrade the firmware.
(5) Bus 470 Ω EOL.
(6) ATS bus.
(7) CON3 and CON1 — connectors to radio board.
(8) Flash jumper. Put jumper in Flash position (bottom pins) to allow
the firmware upgrade.
(9) DIP switches.
(10) Tamper switch.
Mounting location
The ATS1235 can be mounted on any interior wall.
Caution:
When installing the ATS1235 expander, it is
important to minimize any electromagnetic interference from
the environment the ATS1235 expander is installed in. Ensure
that the ATS1235 expander is a minimum of one meter away
from mains power lines (Figure 3, item 1), metal cabinets
(Figure 3, item 2) or any large metallic objects, and any source
of electromagnetic interference such as door bell transformers
and fuse boards. Avoid excessive metal or electrical wiring, for
example, furnace and utility rooms.
Avoid areas where the wireless DGP may be exposed to
moisture.
Mounting the ATS1235
Figure 2
(1) Housing base
(2) Mounting holes
1.
Remove power from the ATS control panel before
installation.
2.
Remove the ATS1235 plastic cover.
3.
Hold the base of the ATS1235 against the mounting
surface and mark the two mounting holes.
4.
Drill holes and insert screw anchors, if required.
5.
Secure the unit to the mounting surface with the screws
provided. If mounted near metal, give the antenna as
much clearance as possible.
P/N 466-5601 (ML) • REV A • ISS 14APR21
(3) Cable entry
(4) Pry-off tamper mounting
location
Connecting the ATS1235
See Figure 1.
1.
Connect the four bus cable wires to the terminal strip
CONN10 on the DGP.
+12 to +12V
GND to 0V
D+ to D+
D− to D−
2.
Connect the bus cable to the ATS control panel bus.
Connect the power cable to the control panel auxiliary
power, or run a separate power cable to the nearest mains
powered DGP. When using a remote DGP power supply,
0 V must be connected to the panel and the DGP as well.
Note:
The TERM jumper (terminator) can be placed on the last
device on the bus.
Wiring specifications
The ATS1235 can be located up to 1500 m from the ATS
control panel using a WCAT52/54 cable. This cable has a core
with a gauge of 24 AWG, the diameter is 0.52 mm and the
area is 0.22 mm².
Closing the ATS1235 housing
1.
Replace the plastic cover.
2.
Mount sensors and 868 MHz AM repeater as required.
A repeater can be added later if sensor performance or
signal strength is found to be inadequate.
Powering up the ATS1235
1.
Before powering up the panel and receiver module, verify
that all wiring at the panel and ATS1235 wireless receiver
is correct.
2.
Connect the panel backup battery and AC power.
The sensitivity is reduced by −6 dB by default while the
Note:
DGP is in programming mode. The sensitivity can be changed
in "Menu 12, Receiver Sensitivity".
Specifications
Advisor Master: ATS1235 requires
Compatibility
Advisor Master control panel firmware
version V04.09.16 or later.
Advisor Advanced: ATS1235 requires
Advisor Advanced control panel firmware
version MR_017.017.0067 or later.
868 MHz AM (crystal and SAW) Learn
Mode wireless sensors.
Wireless zones
16 or 32 per DGP (programmable)
Fobs
16
Power required
9.5 to 14.4 V
70 mA ±10%
Wireless operating
868.0 to 868.6 MHz
frequency
Maximum power output
14 dBm
Maximum recommended
1500 m using WCAT52/54, two twisted
bus distance
pairs, shielded data cable.
−10 to +55°C
Operating temperature
Maximum relative humidity 95%, noncondensing
Dimensions (L x W x H)
16.5 x 11.5 x 4 cm
Weight
350 g
±2%
3 / 22