Ⅴ. Common failure analysis
Common failure
After power connecting,
switch it on and the Juicer
doesn't work.
Motor gives out disguis-
ing smell during the first
few times of use
Stop during operation
Fruit contains much
pomace
Few fruit comes out
Abnormal vibration or loud
noise
Obstructed cutter
TECHNICAL SPECIFICATION
- Voltage: 220-240 V ~
- Frequency: 50Hz/60Hz
- Power: 500 W
Cause analysis
1. Center Ring was not
installed in place;
2. Top Cap was not installed in
place;
3. Microswitch broken
Normal phenomenon
1. The voltage is below level;
2. Ingredients are excessive;
3. Exert excessive pressure to
press the Pusher;
4. When the motor is overheat-
ing, the motor will have protec-
tion.
1. Juicing Sieve broke;
2. Much pomace accumulated in
Center Ring.
1. Much pomace accumulated in
Center Ring;
2. Exerted large pressure on the
Pusher.
1. Juicing Sieve was not
installed in even position;
2. The Juicier was not placed
smoothly and steadily or its foot
pad came off;
3. Voltage is overhigh;
4. Ingredients are excessive.
Cutter was twined by ingredients
or deadly locked.
. 7 .
Solution
1. Put the Center Ring in place;
2. Put the Top Cap in place;
3. Replace Top Cap;
4. Put all parts in place.
If the smell remains after using for
several times, please send it to
specified maintenance station.
1. Check if the voltage is too low;
2. Disconnect power source and
take redundant ingredients out;
3. Lightly press the Pusher;
4. Switch it off for 20-30 minutes
before use it again.
1. Replace the broken Juicing
Sieve;
2. Replace the Center Ring.
1. Clean the Center Ring;
2. Lightly press the Pusher.
1. Put the Juicing Sieve in place;
2. Put the Juicer smoothly and
steadily or put the foot pad in
place;
3. Check if the voltage is overhigh;
4. Disconnect the power and take
excessive ingredients out.
Disconnect the power, take
ingredients out and cut it into
smaller pieces.