Safety

Grounding Instructions

This appliance must be grounded. If it should
malfunction or breakdown, grounding provides a path
of least resistance for electric current to reduce the
risk of electric shock. This appliance is equipped with
a cord having an equipment-grounding conductor
and grounding plug. The plug must be inserted into
an appropriate outlet that is properly installed and
grounded in accordance with all local codes and ordi-
nances.
Improper connection of the equipment-grounding
conductor can result in a risk of electric shock.
Check with a qualified electrician or service
person if you are in doubt as to whether the outlet
is properly grounded. Do not modify the plug
provided with the appliance - if it will not fit the
outlet, have a proper outlet installed by a
qualified electrician.
This appliance is for use on a nominal 120-volt circuit,
and has a grounded plug that looks like the plug illus-
trated in sketch A. A temporary adapter looks like
adapter illustrated in sketches B and C, may be used
it connect this plug to a 2-pole receptacle as shown in
sketch B if a properly grounded outlet is not available.
The temporary adapter should be used only until a
properly grounded outlet (sketch A) can be installed
by a qualified electrician. The green colored rigid ear,
lug or the like extending from the adapter must be
connected to a permanent ground such as a properly
grounded outlet box cover. Whenever the adapter is
used, it must be held in place by a metal screw.
Figure 1: Method of securing the appliance cord to the extension cord set
Cord set
(A) Tie cord as shown
Ampere rating
More than A
Not More than A
10
6
Appliance cord
Extension cords ratings and measures
Volts
12
120 V
8.644-074.0 Manual - Trident Hillyard V15XP
Grounding Pin
GROUNDING CONNECTION
USING AN ADAPTOR
Grounded
Outlet
FIGURE A
Adaptor
Tab for Grounding
Screw
FIGURE C
Note: Adaptors are not allowed in Canada.
NOTE: In Canada, the use of a temporary adapter
is not permitted by the Canadian Electrical Code.
Electrical
In the USA this machine operates on a standard 15
amp 115 volt A.C. power circuit. The amp, hertz, and
voltage are listed on the data label found on each
machine. Using voltages above or below those
indicated on the data label will cause serious damage
to the motors

Extension Cords

If an extension cord is used, the wire size must be
according to the table, and must be limited to 50 feet
(15.5m) in length.
(B) Connect plug and receptacle
Total length of cord
7.62m (25ft)
15,24m (60ft)
mm² (AWG)
0.83 (18)
1.3 (16)
Grounded
Outlet Box
Adaptor
Metal Screw
FIGURE B
30,48m (100ft)
2.1 (14)