Electrical Connections - RIB TOUCH Wi-Fi 2.0 Instalación

Costa mecánica sin cables
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

G
B
TECHNICAL DATA / INSTALLATION
TOUCH Wi-Fi in combination with the electronic device MASTER Wi-Fi conforms to standard
EN 13849-2 (2013) and when used with a RIB electronic control panel it is a PL "c" Category 2
protection device for protecting persons/things from collisions caused by mechanical moving
parts such as automatic gates or doors. The obstacle is detected along the entire length of the
device axially and perpendicularly.
The TOUCH Wi-Fi strips can be positioned anywhere without needing to use electrical wire. The
WiFi system (made up of a TOUCH Wi-Fi and MASTER Wi-Fi) operate at a frequency of 868,3 MHz.
The MASTER Wi-Fi card communicates constantly with the TOUCH Wi-Fi strips and always
signals collisions or malfunctions.
Each TOUCH Wi-Fi has its own internal ID code that distinguishes it from the other devices.
The WiFi system is an active security system because it constantly verifies proper functioning
of the TOUCH Wi-Fi devices and battery condition.
When using RIB electronic control panels you can run auto-tests on the system.
With RIB actuators, RIB electronic control panels having the auto-test function and RIB safety
devices you can create an installation that conforms to the European Directives and Norms
in force.
After completing the system, you must make sure it conforms to standard EN 13241-1.
RIB shall not be liable for any damages caused by improper, incorrect or unreasonable use of
the product.
If you remove the power of the MASTER Wi-Fi for a long time, the TOUCH Wi-Fi safety
strips and the NOVA Wi-Fi photocells will exhaust faster than normal the charging of their
batteries. Keep the MASTER Wi-Fi always properly fed to ensure a period of three years for
the batteries-life, as stated by RIB.
If for instance, the power to the system is cut off every night, the photocells and the
safety strips will regularly and constantly search for the MASTER Wi-Fi without finding it.
Therefore, the life span of the batteries may be reduce to less than one year.
The installer of the safety device must make sure that the end user know the following:
- That the safety devices must be made known to all appropriate people.
- That the passages to reach the devices must be kept clear from any obtsacle.
- About the procedures for cleaning so to avoid the dangerous building up of material.
- The possible details for a restart of the system after an emergency or accidental stop caused
by the control system.
ATTENTION:

ELECTRICAL CONNECTIONS

BAT
Lithium battery AA 3,6V (code ACG9517)
DIP
Microswitches for combination and identification
DL1 (red)
Radio transmission signal
EDGE
Terminals for connecting to mechanical strip contact
PROG S1
Programming pushbutton
S1
BAT
DL1
14
EDGE
DIP

Publicidad

Tabla de contenido
loading

Productos relacionados para RIB TOUCH Wi-Fi 2.0

Este manual también es adecuado para:

Acg3016b

Tabla de contenido