Intended Use; Technical Data; Before Start-Up - Würth 0891 385 008 Traducción Del Manual De Instrucciones De Servicio Original

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 30

Intended use

Pressurised spra appliances are intended for the
spra ing of alkaline cleaning and care products.
These agents must be approved b the manufacturer
for use in spra appliances.
Nitric, acetic and propanoic acids ma onl be used
in concentrations up to 10%, phosphoric and sul-
phuric acid up to 30%, and potassium and sodium
h droxide solutions up to 20%.
Not suitable for
• Combustible li uids
• Corrosive substances (certain disinfectant and
impregnating agents, acids, bases)
• Ammonia containing li uids
• Li uids ith temperatures greater than 40°C
• Wetting agents (surfactants) solvents and solvent
containing li uids, hich could trigger or pro-
mote cracking in the plastics used
• Viscous, stick or residue forming li uids (d es,
grease)
• Use in food production
o not under an circumstances use
• xternal pressure sources ithout an origi-
nal-e uipment compressed air filling valve
• For de agration
• For storage of li uids
• As an e e ash
mproper use can result in dangerous inju-
ries and harm to the environment.
The user is liable for damage in the event
of improper use.
cope of deliver [ g. ]
Overvie
1 Container
2 Pump
3 Hose
4 Instructions for use
5 Spra ing tube
6 Shut-o valve
Parts kit
7 Carr ing belt
26 Union nuts
27 Elbow
14

Technical data

tem
Max. filling uantit
Total content
Max. spra ing pressure
Max. operating tem-
perature
mpt
eight
Total weight
Container material
Method of carr ing
Technical residual
uantit
Max. volume o
Recoil
Pressure change from
0 to 3 bar
ssembl
Fasten the carr ing belt [7] to the container [1].
(Fig. 1)
Push the hose [3] into the seating [9] and secure
it with the union nut [26]. (Fig. 2)
Push the hose [3] on to the shut-o valve [6] and
secure it with the union nut [26]. (Fig. 2)
Scre the spra tube [5] on to the shut-o
valve [6]. (Fig. 2)
Screw the elbow [27] on to the spra tube [5].
(Fig. 2)

Before start-up

Visual inspection:
Are container [1], pump [2], hose [3], shut-o
valve [ ], piston manometer [8] and spra tube [5]
and elbo [27] ith nozzle, undamaged?
Note:
Check particularl the connections con-
tainer – hose and hose – shut-o valve,
as ell as the condition of the pump
thread and spra tube.
0891 385 008
5 l
8 l
3 bar
40 °C
2.6 kg
7.6 kg
Pol eth lene
On the side
< 0.07 l
1 l/min
< 5 N
At least 5000 x

Publicidad

Tabla de contenido
loading

Tabla de contenido