Heater Stand And Location; Gas Requirements; Leakage Test - Mercalor MT01556 Manual De Instrucciones

Ocultar thumbs Ver también para MT01556:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

HEATER STAND AND LOCATION

The stove is primarily for outdoor use.
Always ensure that adequate ventilation is provided
Always keep an adequate distance from combustible material, ie 100cm at the top and at least
100cm at the sides.
The stove must be placed on a firm and level floor.
Never place the range in an explosive atmosphere such as areas where gasoline or other
flammable liquids or gases are stored.
To protect the stove from strong winds,anchor the base securely to the ground with screws.
.
Use only propane or butane gas.
The pressure regulator and hose assembly to be used must comply with local standard codes.
The installation must comply with local codes,or in the absence of local codes,with the standard
for the storage and handling of liquefied petroleum gases.
A dented,rusted or damaged cylinder can be dangerous and should be checked by your
cylinder supplier. Never use a cylinder with a damaged valve connection.
Never connect an unregulated cylinder to the stove.
Range gas connections are leak teted at the factory prior to shiopment. A complete gas
tightness check must be carried out at the installation site,due to possible mishandling during
shipping or the application of excessive pressure to the stovel
Make a soap solution of one part liquid detergetn and one part water. The soap solution can be
applied with a spray bottle,or rag. Soap bubbles will appear in the event of a leak.
The heater should be checked with a full cylinder.
Make sure the safety control valve is in the OFF position. Turn on the gas supply.
In the event of a leak,shut off the gas supply. Tighten leaking fittings,then turn on gas supply
and recheck.
Never do a leak test while smoking.

GAS REQUIREMENTS

LEAKAGE TEST

21

Publicidad

Tabla de contenido
loading