CTC 61100N Manual De Usuario
CTC 61100N Manual De Usuario

CTC 61100N Manual De Usuario

Termostatos no programables

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

Non-Programmable
Thermostats
®
61100N
User
Manual
Single Stage Heat / Cool
Conventional or Heat Pump
62100N
Up to 2 Heat / 1 Cool
Conventional or Heat Pump
Model number is located on back of thermostat
1 Specifications
2 Installation
3 Setting User Options
Warning
Turn off power to the heating or cooling
equipment before installation.
Attention
For installation by experienced service
technicians only.
Read all instructions before proceeding.
This thermostat requires 24 Volt AC Power or two (2) properly installed
"AA" Alkaline batteries for proper operation. When connecting 24 Volt
AC Power the batteries may be installed as a backup.
For use only as described in this manual. Any other use will void warranty.
1 Specifications
This thermostat is compatible with:
Electrical and control specifications:
Terminations
4 Operating Your Thermostat
5 Additional Operation Features
6 Thermostat Maintenance
61100N-100-01

Publicidad

Tabla de contenido
loading

Resumen de contenidos para CTC 61100N

  • Página 1 Non-Programmable Thermostats ® 61100N User Manual Single Stage Heat / Cool Conventional or Heat Pump 62100N Up to 2 Heat / 1 Cool Conventional or Heat Pump Model number is located on back of thermostat 1 Specifications 4 Operating Your Thermostat...
  • Página 2 2 Installation Warning Disconnect power before beginning installation. Thermostat Location Install your new CTC thermostat in 5 basic steps: Install the Sub-Base: Drill 3/16” pilot holes in your desired location. Use supplied anchors for drywall or plaster.
  • Página 3: Connect Your Wires

    Provide Power For 24 Volt AC power For primary or back-up power Connect Your Wires Conventional Systems Typical Wiring Configurations NOTE: The “Installer Switch” option will be configured in the next step. Heat Only or Millivolt Set Installer Switch to CONV W1/E [note 4] [note 1]...
  • Página 4 Heat Pump Systems Typical Wiring Configurations NOTE: The “Installer Switch” option will be configured in the next step. 1 HEAT / 1 COOL - No Auxiliary Heat Set Installer Switch to HP O or B [note 2] [note 1] 2 HEAT / 1 COOL - Including Auxiliary Heat (62100N only) Set Installer Switch to HP O or B [note 2]...
  • Página 5 Attach Thermostat to Sub-Base 3 Setting User Options Advanced User Options To enter the User Options menu, hold down both the buttons for 3 seconds until the screen changes and displays the first User Option. Table of User Options User Factory Setting Options...
  • Página 6: Operating Your Thermostat

    4 Operating Your Thermostat Setting the System Control Mode COOL HEAT Additional Switch Position (Model 62100N Only): EMER NOTE: If your model 62100N was configured for a conventional system (CONV) then you will not have the EMER (emergency heat) option and “NO EMER SET”...
  • Página 7 If batteries are installed and they become low, a low battery indicator will appear in the display. NOTE: We recommend replacing the thermostat batteries annually or if the thermostat will be unattended for an extended period of time. Thermostat Cleaning Store this manual for future reference. CTC Thermostats Limited Warranty 61100N-100-01...
  • Página 8: Especificaciones

    Termostatos no programables ® 61100N Manual de 1 Etapa Calefaccion / Aire Acondicionado usuario Convencional o Bomba Termica 62100N Hasta 2 etapas de Calefaccion / 1 de Aire Acondicionado Convencional o Bomba Termica El número del modelo se encuentra en la parte posterior del termostato.
  • Página 9: Instalación

    2 Instalación Advertencia Desconecte la energía antes de empezar a hacer la instalación. Ubicación del termostato Instale su nuevo termostato CTC en 5 pasos básicos: 3 Conecte los cables Instale la sub-base: Perfore agujeros guía de 4,8 mm (3/16 pulg.) en el lugar deseado.
  • Página 10: Conecte Los Cables

    Conecte los cables Sistemas convencionales Configuraciones típicas de cableado NOTA: La opción “Interruptor de instalación” se configurará en el siguiente paso. Calefacción solamente o milivoltaje Configurar el interruptor de instalación en CONV W1/E en el modelo 62100N) [nota 4] [nota 1] Transformador doble o sencillo con 1 etapa de calefacción / 1 etapa de aire acondicionado Configurar el interruptor de instalación en CONV...
  • Página 11: Configure Los Interruptores De Instalación

    Sistemas de bomba de calor Configuraciones típicas de cableado NOTA: La opción “Interruptor de instalación” se configurará en el siguiente paso. 1 etapa de calefacción / 1 etapa de aire acondicionado – Sin calefacción auxiliar Configure el interruptor de instalación en HP O or B [nota 2] [nota 1]...
  • Página 12: Fije El Termostato A La Sub-Base

    Fije el termostato a la sub-base del termostato. 3 Configuración de las opciones del usuario Opciones avanzadas del usuario Para entrar al menú de Opciones para el Usuario, presione los botones por 3 segundos hasta que la pantalla cambie y muestre la primera Opción para el Usuario.
  • Página 13: Funcionamiento De Su Termostato

    4 Funcionamiento de su termostato Configuración del modo de control del sistema apropiada. COOL sistema de aire acondicionado. HEAT Posición de interruptor adicional (para modelo 62100N solamente) EMER calor. NOTA: Si su modelo 62100N fue configurado para un sistema convencional (CONV), no contará con la opción EMER (calefacción de emergencia) y la pantalla destellará...
  • Página 14: Características Funcionales Adicionales

    NOTA: Recomendamos el remplazo anual de las baterías o si el termostato estará desatendido por un periodo largo. Limpieza del termostato limpiadores abrasivos para limpiar el termostato. Guarde este manual para consultarlo en el futuro. Garantía Limitada de los Termostatos CTC en el material o mano de obra. www.supco.com 61100N-100-01...

Este manual también es adecuado para:

62100n

Tabla de contenido