Casselin CVRS43L Manual De Instrucciones página 14

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 26
EN
- The regulator is located at the back of the device
- There are two keys to lower or raise the temperature
- The first liquid crystal indicator corresponds to the compressor, lit when the compressor is running for
cooling
- The second liquid crystal indicator corresponds to the defrost, lit when the automatic defrost is on
- This key corresponds to the LED lighting
1. Set the temperature: Press the button
, the set temperature is displayed. Push the button
Where
to modify and store the displayed value. Push the button
to exit the setting and display the cold room
temperature.
2. If no other button is pressed within 10 seconds, cold room temperature will be displayed.
3. Lighting: Press the button
, it lights up; press again, it stops. Manual defrost with stop/start: Press the
button
and hold for 6 seconds to defrost or stop defrost.
4. Refrigeration LED: During refrigeration, the light is on; When the cold room temperature is constant, the
light is off; During delayed start, the light flashes.
5. Defrost LED: during defrost the LED is on; when defrosting stops, the LED is off. During the delayed
defrost display, the LED flashes.
6. Digital controller reset
When the screen displays "disorder", press the button for 2 seconds until the beep sounds, quickly press
the button for 6 seconds until the beep sounds again, the screen flashes for 3 seconds and restores factory
settings.
Glass pane
Digital control

Publicidad