8. STORAGE AND TRANSPORTATION:
Storage and transportation:
Long term storage of your machine will require some preventive procedures to
guard against deterioration.
Drain the fuel:
1. Turn the 3 in 1 switch to "OFF".
2. Remove the fuel tank cap, remove the filter. Extract the fuel from the fuel tank into
an approved gasoline container using a commercially available hand siphon. Then,
install the fuel tank cap.
3. Fuel is highly flammable and poisonous. Check "SAFETY INFORMATION" , and
carefully immediately wipe off spilled fuel with a clean, dry, soft cloth, since fuel may
deteriorate painted surfaces or plastic parts.
4. Start the engine and leave it run until it stops. The engine stops in approx.
20 mins. Time by running out of fuel.
TIP:
• Do not connect with any electrical devices. (Unloaded operation).
• Duration of the running engine depends on the amount of the fuel left in the tank.
5. Drain the fuel from the carburetor by loosening the drain screw on the carburetor
float chamber.
6. Turn the 3 in 1 switch to "OFF".
7. Tighten the drain screw.
Engine:
Perform the following steps to protect the cylinder, piston ring, etc. from corrosion.
1. Remove the spark plug; pour about one table-spoon of SAE 10W-30 into the spark
plug hole and reinstall the spark plug.
2. Recoil start the engine by turning over several times (with 3 in 1 switchnob off ) to
coat the cylinder walls with oil.
3. Pull the recoil starter until you feel compression. (This prevents the cylinder and
valves from rusting).
4. Then stop pulling.
5. Clean the outside of engine and spay antirust additive.
6. Store the generator in a dry, well-ventilated place, with the cover placed over it.
7. Lay the engine vertically.