ENVIRONMENTAL REQUIREMENTS FOR STORAGE, INSTALLATION AND OPERATION
SUNWAY M XS Model
Degree of protection
Dimensions (mm)
Weight (kg)
Operating ambient temperature
Rated operating temperature
Ambient temperatures for storage and transport
Maximum number of packed SUNWAY M XS inverters
that can be stacked up
Installation environment
Altitude
Operating ambient humidity
Storage ambient humidity
Ambient humidity during transport
Storage and operating atmospheric pressure
Atmospheric pressure during transport
8/26
4600TL
5000TL
414 x 703 x 260 mm
31
31
-25 °C ÷ +60 °C
-25 °C ÷ +45 °C
-25 °C ÷ +70 °C
Pollution degree 3 or better.
Do not install in direct sunlight and in places exposed to
conductive dust, corrosive gas, vibrations, water sprinkling or
dripping; do not install in salty environments.
Up to 2000m a.s.l. For altitudes ranging from 2000m to
3000m a.s.l. derate the output current by 1% every 100m. For
higher altitudes, please contact Elettronica Santerno.
3
0 % to 100 %, 1 g/m
to 25 g/m
freezing (class 3k3 according to EN 50178).
3
0 % to 100 %, 1 g/m
to 25 g/m
freezing (class 1k3 according to EN 50178).
Max. 100%. Up to 60g/m
the equipment is not running (class 2k3 according to EN
50178).
86 kPa to 106 kPa (class 3k3 and 1k4 according to EN
50178).
70 kPa to 106 kPa (class 2k3 according to EN50178).
QUICK START GUIDE
6000TL
7500TL
IP65
35
3
3
, non-condensing and non-
3
, non-condensing and non-
3
, condensation may appear when
35

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Sunway m xs 5000tlSunway m xs 6000tlSunway m xs 7500tl

Tabla de contenido