UK
Cleaning, Care & Maintenance
•
Always turn off and disconnect the appliance from the power supply before
cleaning.
•
Always allow the appliance and oil to cool before cleaning.
•
Check the temperature with a suitable probe thermometer; 40ºC is the MAXIMUM temperature at
which oil should be removed.
•
For best performance, BUFFALO recommend that the appliance is cleaned after each day of operation.
•
Pull the air filter out of its slot on the bottom of the appliance. Clean with a vacuum cleaner.
Note: Failure to clean the appliance regularly may result in premature activation
of the thermal cut-out switch.
Empty and clean the oil tank
•
When the oil has cooled sufficiently, lift the tap lever and rotate anti-clockwise to the ON position. Let
the drained oil flow into a container.
Tap: OFF position
•
If the oil is to be reused then filtering it before refilling will extend the oil's cooking life.
•
Use a suitable detergent to clean the oil tank.
•
Let it dry well, ensuring no moisture enters the inside of the appliance.
Cleaning all removable parts
•
Use warm, soapy water and a soft brush to clean the lid, basket and batter plate.
•
Dry thoroughly.
•
A BUFFALO dealer or qualified technician should carry out repairs if required.
Troubleshooting
Error indications
HEATING
IGBT on the PCB is
indicator light
overheated. Buzzer
flashes once
alarms.
continuously
6
CP793_CT012_ML_A5_v3_20180927.indb 6
Description
Probable Cause
Check ventilation
slots for dirt and
grease. Make sure
there is enough
space around the
appliance.
Tap: ON position
Solution
1. Switch the unit off and let it cool.
2. Check the filter and clean if
necessary.
3. Re-start the unit.
Note: If it occurs frequently, call
BUFFALO agent or qualified technician
2018/9/27 09:54