The device doesn't turn ON
32/68
24V>230V inverter:
Battery not suitable (12V
instead of 24V)
Thermal protection: the inner
temperature of the inverter is
above 45°C
Overconsumption
Output short circuit
Battery overvoltage
WWW
Replace your 12V battery with a 24V battery
Stop the consumer. Let the inverter cool
down and improve the ventilation.
Check that the power of the connected
device is compatible with the power of the
inverter or if possible reduce the
consumption of the connected devices.
Check the connections of your devices to
supply.
Check that the voltage of the connected
battery is compatible with the inverter.
If it is defective, replace the battery.
.
.