under shelter form the weather. Product installation must be
carried out by qualified personnel and in compliance with these
instructions and all national and local regulations concerning
installation and safety. Do not place the radiators in rooms
with chlorine vapours or corrosive fumes, e.g. pools, saunas,
thermal pools.
5. Positioning in bathrooms
Position the radiator so that no obstacle is present at a minimum
distance of 100 mm and/or within the reach of the radiator
handle.
It is forbidden to install the radiator inside shower enclosures or
in areas where it is potentially exposed to water jets.
6. Wall mounting
For wall mounting of the radiator, use the specific template
supplied. Follow the instructions contained in the fastening
kit for assembling and adjusting the supports. The fastening
systems (screws+blocks) are suitable for compact walls or
hollow brick walls. For walls made of different materials, the
installer is responsible for the use of suitable fastening systems.
7. Hydraulic connection
The Window towel warmer is supplied with a valve kit with
thermostatic head as standard.
The kit contains the instructions for assembly and use of the
thermostatic head valves.
When the hydraulic connection to the system has been carried
out, it is recommended to release air from the towel warmer by
turning the no.3 bleed valves.
A proper cover, positioned by means of no.2 self-tapping
screws, covers the valve body.
- 10 -
Cod. 1910000000355 - nv02