EN
AC Power
This product has an auto-ranging power supply that can work with an input voltage range of 100–240 VAC, 50/60 Hz.
AC Plug
Connection
AC Live
AC Neutral
AC Ground
Fuse Replacement
1. Disconnect this product from the power outlet.
2. Using a flat-head screwdriver, unscrew the fuse holder cap from the housing.
3. Remove the blown fuse and replace with another fuse of the same type and rating (F 20 A, 250 V).
4. Screw the fuse holder cap back in place and reconnect power.
Product Overview
Front Panel Overview
Front Panel Description
#
Name
Function
POWER: green, indicates power connection
NET: yellow, indicates ethernet connection
1 LED indicators
ACT: white, indicates controller signal
ERROR: red, indicates an error (see Warning Messages in the menu)
Rotate to navigate upwards or downwards through the menu list, and increase or decrease a
2
<MENU> knob
selected numeric value. Push to enable the currently displayed menu option or set the currently
selected value into the selected function.
<ESC/BACK>
3
Exits the current menu or function
button
Rear Panel Overview
Fuse
Holder
Rear Panel Description
#
Name
Function
1
IN/THRU
RJ45 connectors for ethernet input and through
2
DMX IN
5-pin phoenix connector for DMX input
3
DMX OUT
5-pin phoenix connector for DMX output
4
WALL CON
RJ12 connector for LΩGIC Wall Controller
5
OUTPUT 1
RJ45 connector for output to first group of LΩGIC products
6
OUTPUT 2
RJ45 connector for output to second group of LΩGIC products
2
QUICK REFERENCE GUIDE
Wire (U.S.)
Black
White
Green/Yellow
1
Power
Input
Wire (Europe)
Brown
Blue
Green/Yellow
LCD Display
2
1
1
2
3
4
Screw Color
Yellow/Brass
3
5
6
LΩGIC Drive 2X QRG Rev. 7
Silver
Green