Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 36
Display shows
The flue blower is defec-
"Alar fan fail"
tive or the printed circuit
board cannot measure its
speed.

9. TECHNICAL DATA

Model
Type of stove
Capacity (*)
Power consumption (ignition/normal operation)
Power supply
Thermal efficiency at nominal/reduced capacity (*)
CO level at 13% O
2
Average dust content at 13% O
For rooms up to**
Flue diameter
Flue gas temperature at nominal/reduced capacity
Required chimney draught
Required flue choke valve
Can be used on a chimney combination with flue
Type of fuel (****)
Nominal length/diameter of fuel
Pallet hopper volume
Autonomy (min-max)
Main air vent
Recirculation blower
Air filter
Net weight
(*) Meets EN 14785
(**) only indicative, varies per country/region
(***) To be determined by authorised professional fitter
Either the flue blower, the printed circuit
board or the speed sensor is defective, or
the wiring is damaged or loose. Fix the de-
fect. Only to be done by a Stover-approved
technician
nominal/reduced capacity (*)
2
270
Wooden pellets
kW
2650 - 7000
W
300 / 100
V/Hz
230/~50
%
91 / 92,7
%
0,01 / 0,04
mg/Nm³
18,4
170
mm
80
°C
128 / 77
Pa
11
Possible***
No
Ø 6 mm
Din+/Önorm+/
EN+
mm
30 / 06
kg
13
h
8 - 22
Yes
Yes
No
kg
81
4
129