Operating manual
• Check, at least at the end of the working day, that the dust bag inside the hoover is full.
• The maximum capacity of the dust bag is 7 kg and 20 l volume: do not exceed this limit !
• In the event that the removed bag shows tears, proceed with care and following the internal standards of behaviour
in the presence of explosive atmospheres in accordance with the Atex Directive 2014/34/EU.
• Do not use the same dust bag more than once and use ONLY the GYS dust bag with code 058880.
• Spare bags should be stored in a dry place.
• For disposal, act in accordance with the law and internal standards of behaviour for handling explosive dusts.
Steps for fitting the dust bag
1 - Carry out this operation with the metal clamp connected to the earth circuit of the installation.
2 - Close the compressed air supply valve on top of the hoover.
3 - Disconnect the quick disconnect power connector on the back of the hoover before opening the rear cover. Use the
flush latches to open the bonnet.
4 - Unhook the flange of the dust bag from the suction port, close the dust bag with the cap provided to prevent dust
from escaping from the bag during transport. Carefully lift the dust bag and place it in a designated area within the
ATEX installation.
5 - Remove any dust deposits inside the bucket.
6 - Place a new dust bag in the bucket, connecting the flange to the suction port.
7 - Check for breaks or tears in the filter cloth.
8 - Close the cover by slamming it shut, making sure not to tear the bag.
9 - Connect the compressed air supply to the rear of the hoover with the quick coupling provided.
Mouth
suction
CONNECTING THE HOOVER
14
Translation of the original
instructions
GYSDUST SELF EXTRACTOR
Désignation:
Aspirateur pneumatique
Produit:
Nom du fichier CAO:
21_0
Ce document est la propriété de la société GYS