LED TEMPERED GLASS
FLOODLIGHTS
Models: 65-541, 65-542, 65-543
INSTALLATION AND SAFETY INSTRUCTIONS
IMPORTANT: Read before installing fixture. Retain for future reference.
WARNING:
• To avoid electric shock or component damage disconnect power before attempting
installation or servicing.
• To avoid electric shock or component damage, do not use the CCT switch and
power range switch after installation.
• This product must be installed in accordance with the applicable installation code
by a person familiar with the construction and operation of the product and the
hazards involved.
• Use caution when handling this product during or after operation as it may become
hot and cause burns. Disconnect product and allow cooling prior to servicing.
• Any alteration or modification of this product is expressly forbidden as it may cause
serious personal injury, death, property damage and/or product malfunction.
• To prevent malfunction and/or electrical shock this product must be properly grounded.
• Risk of fire, minimum 90°C supply conductors.
• All connections should be capped with UL approved wire connectors.
Model #
Wattage Selectable
65-541
15W/25W/35W
65-542
45W/60W/80W
65-543
100W/125W/150W
INSTALLATION: Prior to installation, connect wires as shown in wiring diagram.
KNUCKLE MOUNTING (Mounting plate included. Suitable for
15W/25W/35W and 45W/60W/80W models.)
STEP 1: Secure the fixture using the 1/2" male thread to a 1/2" female
thread in junction box (or with provided mounting plate) or landscape
post as shown in Figures 1 and 2).
STEP 2: The knuckle arm allows 180° rotation as shown in Figure 2.
YOKE MOUNTING (Suitable for all models.)
STEP 1: Remove existing mounting provided with the fixture by
removing the securing bolts at the bottom of the fixture housing.
Attach the yoke mount to the pre-tapped holes on the side of the
fixture housing using the provided hardware.
STEP 2: Secure the fixture to wall or floor as shown in Figure 3,
using appropriate anchors (not provided).
STEP 3: The yoke arm allows 90° rotation as shown in Figure 2.
Figure 1
See page 2 for additional bracket installation options.
© Copyright 2022 Satco Products, Inc. 8/22 v1.2
CCT Selectable
Voltage
3000K/4000K/5000K
120-347V
Figure 2
1
Lumens
CRI
1800~4900
5400~11120
80
–30° to 45°C (–22°F to 113°F)
12000~21000
WIRING DIAGRAM
Figure 3
Fixture
Knuckle arm
Hole
Operating Temperature
Satco Products, Inc.
Brentwood, NY 11717