12. Go back to point 4 for each of the programs to modify;
• After 1 minute without any action, the module automatically exits the setting mode;
• After a power cut, the settings are retained, a new setting of the day and time may be necessary;
LOCK/UNLOCK CONTROLS
The controls can be locked to prevent unintentional use. To do this, simultaneously
press the
and
the same way to unlock the controls: the
ADVANCED FUNCTIONS
To have access to the advanced functions of the device, the thermostat must be in Ma-
nual
or Program
Calibration
A difference between the setpoint temperature and the temperature actually measured
in the room is possible, it is generally due to the installation conditions of the heater
(location, power / volume, insulation of the room, ..). Calibration adapts the thermostat
setting to actual room conditions.
1. Place the heater in Manual mode on 20 ° C and wait several hours;
2. Measure the room temperature using a thermometer and calculate the difference:
deviation = measured temperature - setpoint temperature;
3. Press the
4. Press
,
5. Set the new value with the
6. Press
to exit;
Maximum temperature
The heater makes it possible to record a maximum temperature (between 19 °C and 28
°C) which cannot be exceeded during adjustments. By default, it is set to 28 °C.
1. Press the
and
2. Press
to display
3. Press
,
4. Set the new value with the
5. Press
to exit;
Heating indicator in standby mode
After a few seconds without any action, the display of the control box turns off automa-
tically, except the heating LED which lights up when the heating element is supplied. It
is possible to set the thermostat so that this indicator goes off when the display of the
thermostat goes off.
1. Press the
and
2. Press
twice to display
3. Press
,
4. Press
to display
5. Press
to exit;
keys for more than 3 seconds: the
mode.
and
keys at the same time for more than 3 seconds to display
flashes alternately with the currently set deviation;
and
keys at the same time for more than 3 seconds to display
;
flashes alternately with the currently set maximum temperature;
and
keys at the same time for more than 3 seconds to display
;
flashes alternately with
;
symbol appears.
keys (between -3 °C and + 3 °C);
keys (between 19 ° C and 28 ° C)
;