PREPARATION (Continued)
Check area above installation location to be sure that wiring can run to the planned location and that duct work can be run
and the area is sufficient for proper ventilation.
Inspect duct work and wiring before proceeding with installation.
Before installation, provide inspection and future maintenance access at a location that will not interfere with installation work.
IMPORTANT: Attic access is required for proper installation. You may need the help of a second person to install this fan:
one person on the attic side and one on the room side.
Installation may vary depending on how the previous bath fan was installed. Supplies necessary for the installation of your
bath fan are not all included; however, most are available at your local home improvement or hardware store.
DIMENSIONS
Ceiling
Opening (L)
Opening (W)
9-1/4 in.
WIRING
TYPICAL INSTALLATION
Ceiling
Ceiling
Opening (H)
9-1/4 in.
6 in.
Housing
Dimension (L)
9 in.
WARNING: Wiring must comply with all applicable electrical
codes. Turn off power before removing or installing connectors.
WARNING: COPPER TO COPPER ONLY. Do not use
aluminum wire.
CAUTION: Accessory part (quick connector) should meet
installation instructions below.
House
wires
NOTE: The connector is reusable on solid wires of the same wire
gauge or smaller. Donot reuse the connector on stranded wires.
• Strip wires 3/8 in. - 1/2 in.
• Grip the wire firmly and push the stripped end of the wire into the open
port of the connector. Use only one conductor per port.
• Verify the stripped end of the wires is fully inserted to the back of the
connector.
CAUTION: Wiring maximum temperature rating 221˚F (105˚C).
600V maximum for building wiring and 1,000V maximum for signs
and light fixtures. The acceptable wire range is 12-18 AWG Sol. Cu.
The ducting from this fan to the outside of the building
has a strong effect on the airflow, noise and energy use
of the fan. Use the shortest, straightest duct routing
possible for best performance, and avoid installing the
fan with smaller ducts than recommended. Insulation
around the ducts can reduce energy loss and inhibit
mold growth. Fans installed with existing ducts may
not achieve their rated airflow.
5
Housing
Housing
Dimension (W)
Dimension (H)
9 in.
5-25/32 in.
Quick
connect
Product
wires