Charging Modes
The IBC800 has three (3) modes. The Lithium charge mode require the mode button
.
to be pressed and held for three (3) seconds to enter the enhanced mode. This "Enhanced" modes
require your full attention before selecting. Do not operate the charger until you confirm the
appropriate charge mode for your battery. Below is a brief description:
For charging 12-volt Flooded, Gel, Maintenance-Free batteries.
14.5V
For charging 6-volt Flooded, Gel, Maintenance-Free batteries.
For charging 12.8-volt lithium iron phosphate batteries. When
14.5V
Charging
Your Pro-User IBC charger can easily be configured to charge many different types of batteries.
The
following recommendations should, however, only be seen as guidelines. When in doubt, always consult
the battery manufacturer for further instructions.
Note: Depending on the condition of the battery, the charger adapts the charging currents to ensure
optimum charging of the battery. Only during the main charging phase, the battery is charged with the
maximum charging current. Shortly before the maximum charging capacity has been reached the
charging current is reduced. This ensures a gentle and best possible charging up to the battery's
maximum capacity.
The battery charger must be connected to the battery according to the instructions above.
Starting the charging process:
Once you have established that the battery clamps or eyelets have been correctly connected,
1.
you can start the charging process. To do so, insert the charger plug into the AC socket.
The charger will start in Standby mode, indicated by the STAND BY LED.
2.
Press the mode button to select the appropriate charge mode (press and hold for three seconds
3.
to enter an enhanced charge mode) for the voltage and chemistry of your battery. The selected
charge mode LED will illuminate.
LED DISPLAY
8
12V NORM
0.8A
6V NORM
When selected, the LED will illuminate.
7.3V
0.8A
12.8V LITHIUM
Press & Hold Mode
selected, the LED will illuminate.
0.8A
1.2-26Ah Batteries
1.2-26Ah Batteries
2Ah-15Ah Batteries