OPERATING AND MAINTENANCE MANUAL
PYD SERIES SOLAR INVERTER
6.1 Quick configuration for asynchronous motor
b0-00 Engine class 0
b0-01 Control mode 2
d0-00 Motor power ( KW of motor )
d0-01 Motor Voltage (3~230V or 3~380V)
d0-02 Motor current (A, motor amperage)
d0-03 Motor Frequency (50-60 Hz)
d0-04 Maximum motor revolutions per minute ( 3000-3500 RPM )
6.2 Quick configuration for permanent magnet motor
b0-00 Engine class 2
b0-01 Control engine 0
d0-00 Motor power ( KW of motor )
d0-01 Motor Voltage (3~230V or 3~380V)
d0-02 Motor current (A, motor amperage)
d0-03 Motor frequency (depends on the model)
d0-04 Maximum motor revolutions per minute (depends on model)
d0-30 - 11 ---------- motor and pump already installed
d0-30 - 12 ---------- engine without hydraulics
Once you have selected 11 or 12, tune appears on the screen and you press the green RUN button
the inverter will start to study the motor to keep it always within its optimum values.
11 is for the start-up of a pump already installed in the well.
12 is for the motor without hydraulics for any test or failure detection out of the water.
7. ALARM CODES
Code
A-LP
Low voltage rest
A-LS
Light standby
A-LL1
Underload protection
A-TF
Full protection
Protection against lack of
A-LL
water
www.proindecsa.com / proindecsa@proindecsa.com
Name
If the value is lower than A1-09, the low voltage alarm shall be
activated.
If the conditions of A1-22/23 are met, the light standby alarm will
be activated.
If the conditions of A1-25/26 are met, the underload protection
alarm will be activated.
Set the DI terminal to 52, enable ON.
Set DI terminal to 53, enable ON
Description
38