- disconnect the plug and take out the water tank (7),
- remove the grid (13) as shown at picture 6,
- remove the net air filter (12) gently from the filter grid (13),
- clean filter every two weeks with a vacuum cleaner. Run a vacuum cleaner lightly over the surface of the air filter (12) to remove dirt. If the
air filter (12) is exceptionally dirty, wash it with warm water and a mild cleanser and dry thoroughly. Dehumidification performance may
decrease when the filter is clogged with debris.
- put the filter inside the filter grid and assemble them back into the device housing.
8. Don't clean the device with gasoline, thinner or liquid detergent.
9. Storage: when the device is not being used for a long period of time and you want to store it note the following steps:
- Empty any water left in the water tank.
- Fold up the power supply cord (8) and put it inside the water tank (7) inside.
- Clean the net air filter (12).
- Storage in a cool and dry place.
TROUBLE SHOOTING
If a condition listed below occurs, please check the following items before calling customer service.
Problem 1: The device does not operate.
Possible reason 1: Has the power cord been disconnected?
Solution of problem: Plug the power cord into the outlet.
Possible reason 2: Is the full water tank indicator (H) blinking?
Solution of problem: The tank is full or in a wrong position. Empty the water tank (7) and then re-position the tank.
Possible reason 3: Is the temperature of the room above 35 degree of Celsius or below 5 degree of Celsius?
Solution of problem: Built-in protection device is activated and the dehumidifier cannot be started in the temperature of the room above 35
degree of Celsius or below 5 degree of Celsius.
Problem 2: The dehumidifying function does not work
Possible reason 1: Is the net air filter (12) clogged?
Solution problem 1: Clean the air filter as instructed under "Cleaning and Maintenance" – point 7.
Possible reason 2: Is the air inlet (5) or the air outlet (2) obstructed?
Solution of problem: Remove the obstruction.
Problem 3: No air is discharged.
Possible reason 1: Is the net air filter (12) clogged?
Solution of problem: Clean the air filter as instructed under "Cleaning and Maintenance" - point 7.
Problem 4: Operation is noisy
Possible reason 1: Is the device tilted or unsteady positioned?
Solution of problem: Move the device to a stable, even, sturdy surface.
Possible reason 2: Is the net air filter (12) clogged?
Solution of problem: Clean the air filter as instructed under "Cleaning and Maintenance" - point 7.
Problem 5: E1 Code shown on the digital indicator (J)
Possible reason 1: Coil sensor short circuit or open circuit
Solution of problem: Contact the seller who issued you purchase bill.
TECHNICAL DATE:
Dehumidify capacity at 30°C / 80% RH): 10 liters / 24 hours
Noise level: <= 42dB(A)
Water tank capacity: 2.0 liters
Airflow: 150m3/hour
R290 coolant weight: 45 grams
Rated Input Power: 280W
Power supply: 220-240V ~50Hz
Please transfer cardboard packaging to waste paper. Pour the polyethylene bags (PE) into the plastic container
Worn device should be returned to the appropriate point storage because it is dangerous in the device
ingredients may pose a threat to the environment. The electrical device should be handed over to limit
its reuse and use. If in the device there are batteries you have to take out and give to the point stored separately.
Caution, risk of fire.
Do NOT pierce or burn.
Be aware that the refrigerant may not contain an odor.
Device shall be installed, operated and stored in a room with a floor area larger than 4 m.².
The maximum refrigerant charge amount: 45g.
8