ELECTRIC SHOCK HAZARD
The unit must be electrically grounded. Use only on
GFCI protected receptacles.
Connect to a properly grounded outlet only. Do not cut
off the grounding prong. Do not use with an adapter. Do not
use with extension cords. Do not use with damaged cord or
plug. If unit is not working as it should, has been dropped,
damaged, left outdoors, or exposed to water, return it to an
authorized service center for repair. Unplug cord from outlet
when not in use or when servicing unit.
ELECTRIC SHOCK HAZARD
Keep motor and electrical parts dry.
Do not use outdoors. For indoor use only.
Do not handle plug or unit with wet hands.
Do not operate unit in standing water.
BREATHING HAZARD
When using the HEPA 700 in a containment area, turn
off all sources of power to open combustion
appliances such as fireplaces, boilers, furnaces, water
heaters and HVAC systems to avoid the risk of backdrafting
deadly carbon monoxide fumes.
SKIN OR EYE HAZARD
Skin or eye damage may result from directly
viewing the light produced by the lamp in this
apparatus. Always disconnect power before relamping or
servicing. Replace with UVC frame #124560, a MediClean
Healthcare product of Legend Brands.
This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to
part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and
can radiate radio frequency energy, and if not installed and
used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no
guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following
measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected
• Consult dealer or an experienced radio/TV technician for help
Regulatory approvals - ATWINC3400-MR210CA modules:
United States/FCC ID: 2ADHKWINC3400
Canada/ISED:
o
IC: 20266-ATWINC3400
o
HVIN: ATWINC3400-MR210CA
o
PMN: Wi-Fi and Bluetooth Module
125549A AP 700
Owner's Manual
AP 700 Air Purifier
FEATURES AND OPERATION
UV Light Cartridge – Helps prevent cross-contamination from
bacteria on the HEPA filter.
Electrical Outlets – Connect up to eight (8) AP 700s on a 15-
amp circuit on the lowest speed; four (4) on the highest speed.
Command Hub Technology – Integrates with the free Dri-Eaz
Command Center Pro mobile app enables firmware updates
and 24/7 control. (Download from Apple and Google Play
stores.)
Setup
1. Unwrap the cord completely.
2. Place the AP 700 with the handle up or on back. Ensure that
neither the inlet nor the outlet are obstructed.
3. Plug into a standard 115V GFCI-protected outlet.
4. Remove cover before operating.
FILTERS
To prevent skin or eye damage from the UV light,
always disconnect power before changing filters,
relamping or servicing.
Use Legend Brands AP 700 filters only (see Filter
Options below). Using other filters will reduce filtration
effectiveness.
Control panel indicates when the HEPA primary filter
needs to be replaced. Do not attempt to clean and reuse
filters. Dispose of contaminated filters per local, state
and federal regulations.
Replacing the Prefilter
When using the unit in environments with a high volume of
airborne particles, the prefilter should be replaced more
frequently to help preserve the life of the HEPA filter.
1. Lay unit on its back and release the four (4) buckles. Lift off
the filter door.
2. Remove the prefilter from the filter door and discard.
3. Insert new prefilter into filter door. Ensure that the prefilter is
seated properly on the retention tabs.
4. Replace filter assembly on unit and reattach four buckles.
Replacing the HEPA Primary Filter
IMPORTANT: Do not clean and reuse the HEPA filter. Always
replace the prefilter and remove the UV light cartridge when
replacing the HEPA filter. See "Changing Filters" below.
1.
Unplug cord from outlet, lay unit on its back and release
the four (4) buckles. Lift off the filter door.
2.
Remove the prefilter from the filter door and discard.
3.
Remove the UV light module.
4.
Replace HEPA primary filter carefully, as filter is easily
damaged. Do not use a filter if damaged.
5.
To reinstall the UV light module, hook frame onto tabs
near bottom of unit then snap into place.
6.
Place new prefilter(s) in filter door. Replace filter cover and
lock the four buckles securely.
Scan for
videos and
more info
Legend Brnads, Inc.

Publicidad

loading

Resumen de contenidos para MediClean AP 700

  • Página 1 1. Unwrap the cord completely. Keep motor and electrical parts dry. 2. Place the AP 700 with the handle up or on back. Ensure that Do not use outdoors. For indoor use only. neither the inlet nor the outlet are obstructed.
  • Página 2 Skin or eye damage may result from directly viewing the light produced by the lamp in this apparatus. Always disconnect power before relamping or servicing. Secure Replace with UVC frame #124560, a MediClean Healthcare replacement 1-inch Prefilter product from Legend Brands.
  • Página 3 PELIGRO RESPIRATORIO 1. Desenvuelva completamente el cordón. 2. Coloque el AP 700 con el mango hacia arriba o hacia atrás. Cuando utilice el HEPA 700 en un área de Asegúrese de que ni la entrada ni la salida estén obstruidas.
  • Página 4 Desconecte siempre la alimentación antes de cambiar la lámpara o realizar el mantenimiento. Reemplace por el marco UVC n.° 124560, un producto de MediClean/Legend Brands. Cuando el temporizador de horas de servicio del marco UVC OPCIONES DE FILTRO llegue a cero, siga estas instrucciones para cambiar el marco: Apague y desenchufe la unidad.
  • Página 5 HEPA. l’intérieur seulement. Prises électriques – Branchez jusqu’à huit (8) AP 700 sur un Ne manipulez pas la prise électrique ou l’unité avec les mains circuit de 15 A à la vitesse la plus basse; quatre (4) à la vitesse mouillées.
  • Página 6 à l’entretien. Remplacez par le cadre UVC nº alimentaires, des émanations de peinture et de diluants à peinture, des odeurs d’égouts et de nombreuses autres odeurs 124560, un produit MediClean/Legend Brands. nocives. Lorsque la minuterie des heures de service du châssis UVC •...