The cable of the device should not deviate from the vertical angle at by
more than 30°, which minimizes the risk of a pendulum effect when
stopping a fall.
When using the device, the rope should not be twisted or tied; The rope
may not be entangled with other ones nor may it be caught somewhere or
led near sharp objects; the rope must not touch moving devices.
Before each use, make sure that there are no obstacles within a radius of
3 meters (at least) below the user's work platform.
3.4.
Cleaning and maintenance
a)
Use only non-corrosive cleaning agents for cleaning the surfaces.
b)
After each cleaning, all parts should be thoroughly dried before the device is
reused.
c)
Store the appliance in a dry and cool place protected from moisture and direct
sunlight.
d)
Perform regular inspections of the unit checking technical fitness and any
damages.
e)
Use a soft cloth for cleaning.
f)
Do not use sharp and/or metal objects (e.g. wire brush or metal spatulas) as
they may damage the surface of the material from which the unit is made.
g)
Do not clean the unit with acidic substances, medical agents, thinners, fuel, oils
or other chemicals. It may cause damage to the device.
h)
At the end of the work, the wire rope must be fully inserted back into the
housing; otherwise, it will weaken the retraction force of the winding spring.
i)
After working on rainy days, dry wire rope with a dry cloth to avoid corrosion
and shorten the service life.
j)
Wipe the housing, steel rope, connectors and labels with a clean cloth with
warm water (up to 40°C) and a non-corrosive detergent. The cleaned unit can
be hung upright and dried in natural conditions; avoid direct drying at high
temperatures.
k)
Periodic inspections: periodic inspections should be performed once a year.
Periodic inspection may only be performed by a person qualified in the field of
personal protection equipment. If the unit is used in severe conditions,
inspections should be performed more than once a year. Inspections and
repairs should be recorded in the register:
Date
Register of periodic inspections and repairs
Reason for entry
(periodic inspection
or repair)
Noticed defects, repairs
carried out and other
important information
Date of the
Name and
next
signature
periodic
inspection