USER MAINTENANCE
We recommend inspecting at least the return air inlet filter once every two weeks.
Once there is a noticeable amount of dust, clean all three filters by rinsing them
under running water.
Remove the cool air outlet grille to access the foam filter beneath it. Replace the
grille after cleaning the foam filter.
In dusty locations, consider arranging for an air conditioning technician to clean the
inside before the summer season.
The refrigerant circuit is permanently welded: there is no need to recharge the gas.
INDICATOR LIGHTS
Power (green light)
This shows that the electrical power is on. When the green light flashes, Coolzy is
waiting 1 – 2 minutes for the compressor to start cooling.
Water drop (white light)
In normal conditions, all the water condensed inside the cooler will evaporate into
the air emerging from the warm air outlet. This evaporation increases the cooling
performance in humid conditions.
If you remove the stopper, following the dehumidification instructions, condensed
water flows into the cable drawer instead. The water drop light comes on when the
cable drawer is full of water.
The water drop light also comes on if the cable drawer is not fully inserted and flush
with the back panel.
When it is extremely humid, greater than 95% lasting for several hours, water can
overflow from the cooler into the cable drawer.
If the water drop light is on, carefully remove the cable drawer and empty any water.
If there is no water, then carefully push the drawer into Coolzy until it is flush with the
back panel.
Snowflake (blue light)
The cooler temperature so low that there is a risk that ice may form, damaging the
tubes in Coolzy. Some combinations of low temperature, humidity and atmospheric
pressure can lead to frosting. Allow the fan to operate for a few minutes to warm up
COOLZY-GO Model PC9B User Guide ENUS2022 Rev1.1
5