USING SOLAR PANELS TO CHARGE THE E600 LFP
1. DC5521 Charging Port:
2. GX16MF-5 Charging Port:
panel/array must be less than 95V, otherwise, it will damage the unit! Do not wire more than two 36V solar panels in series.
(36V stands for Vmp, the operating voltage, of the solar panel)
(
Do not support charging from both input ports at the same time.)
E600
LFP
USING SOLAR PANELS TO CHARGE THE E600 LFP
Using the pecron 100W /18V*1 (100W) to charge the E600 LFP
pecron 100W
pecron 100W*1
Using the pecron 200W /36V*1 (200W) to charge the E600 LFP
pecron 200W*1
Using the pecron 200W /36V*2 (400W) to charge the E600 LFP
pecron 200W*2
Y Branch MC4 Charging Cable(+)*1
PV/DC 12V~18V, 100W maximum; VOC(open circuit voltage) of solar panel must be less than 25V;
PV(operating voltage) range 32V~95V, 400W maximum; VOC(open circuit voltage) of solar
18V
36V
MC4 Solar Charging Cable*1
36V
36V
MC4 Solar Charging Cable*1
www.thetatauhome.com
DC5521 Charging Port:
PV12V~18V-100W Maximum Input
GX16MF-5 Charging Port:
PV32~95V-400W Maximum Input
18V is the operating voltage of the solar panels
36V
36V is the operating voltage of the solar panels
36V
Y Branch MC4 Charging Cable(-)*1
36V is the operating voltage of the solar panels