steps: "D.9" to "D.12" or adjust the air intake through the grille and / or the flow of the registers: in this case, go to Section 4.4.1
Primary Registrer and 4.4.2 Secondary Registrer.
2.3 Type of appliance. Combustion chamber in sealed steel treated with Senotherm 600ºC paint and coated inside vermiculite plates
and with galvanized steel convection casing. Ember grill and smoke pipe connexion piece made from cast iron. The device has an
electric ventilation set and it is ready to install. Provision should be made from inside an output for the electric cable. All the inner can
be removed if desired, for easier transportation and installation.
2.4. Insulating procedures. Fireplace room must be built with non-combustible materials and should not rest on the apparatus
and the points of contact (such as the front frame). Inside should not contain flammable or fragile materials such as wood,
wallpaper, glass, chalk paper, etc.).
2.4.1 Apparatus insulation. The fireplace must be insulated with insulation panels (Type A-1, EN13501-1) on its sides, back and
upper part.
CAUTION:
2.4.2 Fireplace room insulation. It is also convenient to use insulation panels on the inner walls of the fireplace (Type A-1, EN13501-
1).
2.5 Safety distances.
2.5.1 Inner fireplace room safety distances. You must be respected the values described in 1.1 Technical characteristics.
2.5.2 Outer fireplace safety distances. Anything fragile or flammable (textile, electronics, wood, paper wall, glass, chalk...) should
be separated of the appliance and respected the safety distances described in 1.1 Technical characteristics.
We must take special care in those fireplaces with wooden shelves or similar: we must prevent and avoid the possibility of hot air that
expels the device falls directly on the wood, in these cases, flammable items should be properly insulated.
2.6 Fireplace room. Fireplace room must be built with non-combustible materials and should not rest on the apparatus and the points
of contact (such as the front frame). Inside should not contain flammable or fragile materials such as wood, wallpaper, glass, chalk
paper, etc.).
2.7 Ventilation. It is imperative that the niche where the appliance is installed ventilation available.
2.7.1 Fireplace room ventilation. The appliance must be provided with an air outlet or inlet diffusers for sufficient air flow as
described in Technical characteristics
2.7.2 Hot air outlet options:
- WITHOUT air outlet pipes connection. Image III-1 of the ANNEXED document. No used the upper air outlet, the fireplace
room air is output from the front of it.
- WITH air outlet pipes connection. Image III-2 of the ANNEXED document. If you want, you can drive the air from fireplace
room to the top or adjoining room. To drive the air you can remove the screws that block the register.
2.7.3 Air supply. An air supply to the room where the device is located must be provided, when an outside air inlet is not used, the
total maximum length must not exceed 6 m and must have the minimum loss of load. This entry cannot be less than 225 cm
note the simultaneous operation with other ventilation devices and / or heating such as exhaust fans, heat pumps, etc. In these cases,
the extraction must be compensated with a corresponding air entry from outside.
2.8 Changes to the device. Any intended change to the equipment must be authorized in writing by Manufacturas Rocal, S.A. We
also recommend using only original spare parts or parts recommended by Manufacturas Rocal, S.A.
3. INSTALLATION
3.1 Installation process. To proceed with the installation, follow the steps outlined in Section III of the ANNEXED document.
WARNING: The second piece of the deflector plate should be install or adjust in case of draught excess, to procede follow the steps:
"D.9" and "D.10". To adjust the door closing follow the steps "D.11" and "D.12".
Important: Before closing the fireplace room where the device will be located check that all mechanisms work correctly.
For the painting and finishing of the firebox enclosure, tapes or protectors are used for areas that are not painted, these tapes MUST
NOT TOUCH THE SHEET OF THE APPLIANCE in any case to prevent that the painting might peel off when removing this tapes or
protectors.
It is recommended to remove the frame before closing the firebox or use a protector that does not contain adhesive.
. USE AND OPERATION
4
4.1 Fuels authorized by the manufacturer. The appliance should not be used as an incinerator and the use of fuels other than
those authorized by the manufacturer are prohibited, including lighting liquids or gels. Only natural wood logs are authorized as fuel
and it is not advisable to use resinous woods.
CAUTION:
- The maximum load allowed by the manufacturer, the measurements of the logs and the height of the
reload must be respected.
- Do not touch or manipulate any part of the appliance when in operation without a protection glove.
- Check that there are no materials left inside the device, paying special attention to the paint spray.
4.2 Efficient combustion. During combustion the flame should not be extinguished, in this case the unburned gases produce
corrosion, dirt in the duct and polluting gases. The air controls must be opened, particularly the secondary one.
4.3 Pilot fire lighting. For a reasonable period of time, approximately 24 hours, it must not exceed 50% of the Maximum load allowed
by the manufacturer. Before lighting the fire, ensure that nothing delivered with the equipment has stayed inside (such as gloves,
spray paint ...)
4.4 Combustion control. The appliance has mechanisms to regulate combustion.
4.4.1 Primary register. The primary register is used to control the air intake in the combustion chamber from the base of the fire,
through the fire grate, and the vermiculite in the back side. The primary register should be used mainly for lighting and, if necessary,
to aid combustion. To locate the register control handle and to know how to use it see picture "D.2" of the ANNEXED document. If
- If the floor contains flammable materials it must be insulated with non-combustible
materials.
2
. Also
11