Description
Battery voltage
(The battery-saver device has cut in. Voltage has fallen below the
value of: 21,5V / 10,4V.)
Fan over current cut-out
(The condenser or evaporator fan overloads the central control
unit above the limited allowed. Possible cause: short circuit or
blockage of fan rotation.)
Compressor locked
(The rotor is locked or the pressure inside the cooling circuit is too
high.)
Minimum compressor rotation speed
(If the cooling circuit is overloaded, the compressor cannot
maintain the minimum rotation speed.)
High temperature on the central control unit
(If the cooling circuit is overloaded or the ambient temperature is
high, the central control unit signals this situation.)
COMMUNICATION ERROR
(There is no communication between the display and the central
control unit.)
Temperature probe
(If the probe short-circuits or is not connected, the system stops.)
Tilt
(The system shut-down device installed to operate in the event of
tilting has cut in.)
When the system is switched off, it is possible to change the temperature unit, choosing between °C (Celsius) or
°F (Fahrenheit).
Press VENT + , VENT – , TEMP + and TEMP – , buttons simultaneously to show the preset unit (°C) on the
display, and the temperature symbol will light up (see fig.6).
Quickly press VENT + or VENT – to select the unit required.
The remote control regulates both the conditioning function and the fan function.
Using the remote control it is possible to:
- Switch the system on and off
- Regulate the temperature
- Regulate the fan speed
- Engage the MAX AC function
- Modify the TIMER function
ENGLISH
ERRORS SHOWN ON THE DISPLAY (AC / FAN)
TEMPERATURE UNIT
REMOTE CONTROL
15/38
Message
Symbol
E1
E2
E3
E4
E5
E6
E7
E8