5. Associating an OCU with an MCU
1.
For a new OCU that has never been associated with an MCU, the following Association process will
need to be done once.
2.
If possible, press and hold the MCU button shown below. If this is not possible the OCU MUST be held
closer to the antenna of the MCU - to ensure it is connected to that OCU rather than any other MCU. If
necessary, move other MCUs away from the machine to be connected to, in order to ensure it connects
to that intended MCU. The logic is: IF an MCU's button is pressed, connect to that MCU, IF NOT connect
to the MCU with the strongest signal.
3.
With the MCU powered up and the OCU in Passive mode (Refer to Step 3), press MCU button (if
possible) and then immediately, for the type of OCU shown, press and hold the two starred buttons for
10 seconds, until the center Status LED goes Blue. Release all buttons and wait a few seconds for
LED1 to flash Green. The OCU and MCU are now associated.
4.
If LED1 does not flash Green or flashes Red, repeat the association process.
NB:
An OCU cannot be associated with more than one MCU.
An MCU can be associated with up to 8 OCUs.
However, if the MCU has already been associated with 8 OCUs, it will not be possible to associate it with
any more OCUs until the existing associations have been cleared, this is done by pressing the button
shown for more than 20 seconds.
When the association process has been completed, verify that the OCU is controlling the intended
MCU before putting to work.