15 Información del producto relativa a la Regulación
Ecodesign Nº 2015/1188
Combustible Gas natural / Propano
Values
Nominal heat input [kW] @ NCV
Minimum heat input [kW] @ NCV
Minimum heat input as percentage of
nominal heat input [%]
η
[%] @ GCV
Thermal
at nominal heat input
η
[%] @ GCV
Thermal
at minimal heat input
Radiant factor RF
[%] @ NCV
nom
at nominal heat input
Radiant factor RF
[%] @ NCV
min
at minimal heat input
el
[kW]
Auxiliary electricity consumption
max
at nominal heat input
el
[kW]
Auxiliary electricity consumption
max
at minimal heat input
Heat output control type
Space heating emissions NOx @ GCV
[mg/kWh]
Seasonal energy efficiency [%]
NCV= Net calorific value
GCV = Gross calorific value
Tab. 11
Valores característicos del rendimiento energético de deltaSchwank
310U
320U
10,0
20,0
7,5
10,0
25%
50%
86,8%
83,2%
87,2%
86,8%
80,6%
78,1%
80,9%
80,6%
0,03
0,04
0,03
0,03
modulating
modulating
60
60
98,2%
99,0%
deltaSchwank
625U
635U
25,0
35,0
12,5
17,5
50%
50%
83,0%
80,9%
85,9%
84,4%
80,3%
78,6%
82,2%
83,2%
0,04
0,08
0,02
0,03
modulating
modulating
60
60
98,9%
97,4%
deltaSchwank
950U
1260U
48,0
58,0
25,0
29,0
48%
50%
82,3%
83,1%
84,6%
85,8%
83,7%
80,9%
82,0%
83,4%
0,17
0,29
0,05
0,11
modulating
modulating
60
60
97,6%
99,0%
46