3000 Series
Art. 3187 - Art. 3187/8
INTERCOMMUNICATION SETTINGS - SW3
SW3
Nr.1
Nr.2
Nr.3
ON
OFF
OFF
OFF
1
2
3
4
ON
OFF
ON
OFF
1
2
3
4
ON
OFF
OFF
1
2
3
4
ON
OFF
ON
1
2
3
4
ON
OFF
OFF
OFF
1
2
3
4
ON
OFF
ON
OFF
1
2
3
4
ON
OFF
OFF
1
2
3
4
ON
OFF
ON
1
2
3
4
ON
ON
OFF
OFF
1
2
3
4
NOTE: Extension 1 is mandatory. On systems with more than one device in an apartment, each device must have a unique
extension ID.
On installations where there are more than one intercom/videophone in the same apartment and intercommunication
between different apartments is required, only one intercom/videophone may be set with this function (SW3.1=ON,
SW3.2=OFF, SW3.3=OFF, SW3.4=OFF). The other intercom/videophones in the apartment must be set for local intercom-
munication with extension addresses "2-8" (slaves). From the intercom/videophone set for intercommunication with other
apartments it will not be possible to intercommunicate within the apartment but slave extensions 2-8 will be able to inter-
communicate with each other.
SETTING NUMBER OF RINGS
The number of rings can be set to 3 (factory preset) or 6.
To change the number of rings proceed as follow:
• Disconnect the power supply from the system;
• Short the terminals LB and GND;
• Reconnect the power supply to the system checking the privacy on
LED and then remove the short between terminals LB and GND;
• The number of LED flashes will be 1 for 3 rings or 2 for 6 rings.
Each time this operation is carried out the number of rings is tog-
gled between the values 3 and 6.
Art. 3187 - Installation instructions
Intercommunicating intercom for VX2300 digital system
Nr.4
Unit extension
OFF = 1 (master)
OFF = 2 (slave)
ON
OFF = 3 (slave)
ON
OFF = 4 (slave)
ON = 5 (slave)
ON = 6 (slave)
ON
ON = 7 (slave)
ON
ON = 8 (slave)
Intercommunication allowed between units (same unit address)
inside the same flat.
To call an extension pick up the handset then press the "door open" button
as many times as the extension value (Eg. extension 2 two times, 3 three
times etc).
Each intercom/videophone in the same apartment must have a
different extension address, the master address must always be set
except when one of the intercom/videophone is set for apartment
intercommunication (i.e. in a 3 intercom/videophone installation, one
of the intercom/videophone must have the extension address 1 while
the others must have different addresses).
Intercommunication allowed between units (different apartment).
To call an extension pick up the handset then press the "door open" button
as many times as the address value (Eg. extension 10 ten times, 12 twelve
times etc).
CONNECTION TERMINALS SIGNALS
LB
Local Bell contact (put a push button between this ter-
minal and the relevant GND terminal)
AL
Alarm input (not implemented)
GND Ground signal
BUS
BUS connection terminals
BUS
TECHNICAL SPECIFICATIONS
Power consumption:
Working voltage:
- 3 -
Stand-by:
1/3mA
Operating:
30mA
Peak:
50mA
Supplied by the BUS line
66251111 - V5.0 - 15/03/23