Descargar Imprimir esta página

CAME SMA Instrucciones De Montaje Y Puesta En Servicio página 6

Ocultar thumbs Ver también para SMA:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 17
Time functions 1, time unit 2 and time factor 3 (see Table 4.1a for settings)
3.3
The relay picks up when the
loop is activated and drops
out when the loop is exited.
Activation pulse:
The relay picks up when the
loop is activated and drops
out again after the time t.
Sensitivity 4 (see Table 4.1a for settings)
3.4
The sensitivity 5 (=Sensitivity) of the loop detector can be adapted in 9 stages: 51 = Lowest sensitivity, 59 = Highest sensitivity,
54 = Factory setting.
Automatic Sensitivity Boost ASB 5 (see Table 4.1a for settings)
3.5
ASB (=Automatic Sensitivity Boost). ASB is required in order to be able to recognise trailer drawbars after activation.
Frequency 6 (see Table 4.1a for settings)
3.6
Four different frequencies F1, F2, F3, F4* can be set in order to avoid interference when using several loop detectors.
3.7
Direction logic7 (see Table 4.1a for settings)
The direction logic function can only be used with a 2-loop device. Direction logic must have been set in the basic function (see chapter 3.2). Detection
can be performed from:
Output 2 8 (see Table 4.1b for settings)
3.8
In a device with 2 outputs, output 2 can be either activated or deactivated.
Protection against power failure 9 (see Table 4.1a for settings)
3.9
Basic function 2 «Barrier systems» or 3 «quiescent current» must be set for this function.
P 1 = Protection against power tailure activated: The sensitivity is restricted to 1–5 and the time function to h.
3.9.1
Signal characteristics with protection against power failure active (Function 9 = 1)
For Activation (e.g. Barriers)
Basic function 0 = 2 Barrier systems
common
nc
no
common
nc
no
For Safeguarding (e.g. Barriers, bollards)
Basic function 0 = 3 Quiescent current
common
nc
no
common
nc
no
4
Changeover from operation to configuration mode
1- loop device
Display after start-up:
2- loop device
Display after start-up:
2
On delay:
The relay picks up after the
Loop
time t when the loop is acti-
Relay
vated and drops out when
the loop is exited.
Impulse by leaving the loop:
Loop
By leaving the loop,
the relay picks up after
Relay
t t
the time t, relay drops out.
Loop 1 to loop 2
From loop 2 to loop 1
Without power
Without power
Touch the «Mode» button once
1
to change to configuration
mode
Touch the «Mode» button once
1
2
to change to configuration
mode
Loop
t t
Relay
Loop
Relay
t t
from both directions
Initialisation
Free
Initialisation
Free
Mode
1
Sim1
Loop 1 is
Mode
1
Sim1
selected
Off delay:
The relay picks up when the
loop is activated and drops
out after the time t when the
loop is exited.
Max. presence:
he relay picks up when the
loop is activated and drops
t t
out again after leaving, but
at least after the time t.
Occupied
Free
Occupied
Free
Mode
Loop 2 is
2
Sim1
selected
Loop
Relay
t t
Loop
Relay

Publicidad

loading

Este manual también es adecuado para:

Sma 2Sma 230