INTRODUCTION
This filtration station is placed on the general cold water inlet. Provide the necessary spacings for moun-
ting and replacing the filtering elements. The station fears frost and long exposure to bright light.
Leave a space of at least 10 centimeters below the station for maintenance. In the event of high pressure,
greater than 4 bars, install a pressure reducer before the filter.
SETUP
It is recommended to install a shut-off valve at the entry and exit of the station.
1 - Fix the bracket on the station respecting the direction of water circulation.
2 - Screw the valves onto the station after applying sealing tape (Teflon, PTFE) to the threads.
Screw the body of the fittings onto the valves.
3 - Mark the location of the cutout on the water inlet pipe.
4 - Shut off the water supply and release the pressure by opening a faucet.
Then close this faucet and cut the tube using the appropriate tool.
5 - Thread the nut then the ring of the fitting on each end of the tube.
6 - Temporarily position the station on the tube and mark the location of the bracket fixing screws.
7 - Drill the holes.
8 - Insert wall plugs suitable for the wall.
9 - Fix the bracket to the wall using suitable screws.
10 - Tighten the fittings to ensure a seal.
11 - Unscrew the filter holder using the provided key.
12 - Place the cartridge in the bowl and screw in by hand (never with the key).
13 - Slowly open the water supply and check that there are no leaks.
Retighten fittings if leaks are present.
CARE
The cartridge must be replaced regularly, its lifespan depends on the type of cartridge, the consumption
and quality of the water.
1
EN
• Close the 2 shut-off valves.
5
5
14
2
• Place a bucket, unscrew the
bowl with the key and discard
the cartridge.
• Open the valves and control
there is no leaks.
• Retighten fittings if leaks are
present.
3
• Clean the bowl and system cover without using abrasive cleaning
agents.
• Replace the gasket if necessary.
• If the type of cartridge is reusable, then flush the cartridge.
• Place a new cartridge and tighten by hand (never with the key).
Spare parts
Description
Release key
Gasket
4
Reference
3276007344196
3276007344233