Descargar Imprimir esta página

Hiltron security XR200 Manual De Instrucciones página 3

Publicidad

Idiomas disponibles

Idiomas disponibles

security
Made in Italy
BT2014/35/UE
EMC2014/30/UE
NC input for the connection of magnetic contacts or "switch" contacts for roller
shutters.
Signalling LEDs for battery status and transmittion of battery discharge
condition.
Anti-tampering tamper.
ABS external box.
C205 reed magnetic contact included.
Operating frequency: 433,92 MHz
Power supply: battery 9V (included)
Consumption max in st/by: 9 µA
Trigger level for low-battery: 7,4 Volt
Dimensions: 116x30x25 mm
INSTALLATION
The XR200 is installed by securing it adjacent to the door or window to be protected.
CONTACT SWITCH INSTALLATION
As an option with magnetic contacts, you can also connect switch-type shutter contacts to the XR200 transmitter NC input.
ATTENTION : For the programmation of switch contacts follow the instruction :
Digit the left button for 5 seconds, until the green LED is ON.
At the his release, the green LED is OFF, and the option of read of swith cotacts is activated.
For disactive this function, digit the right button for about 5 seconds,until the LED red is ON.
The setting is in memory even when the battery is changed
C205
Reed magnetic contact, N.C.
INSTALLATION
Lead free
Pb
RoHS
compliant
FRAME
10mm max.
XR Series transmitter with NC line input
CHARACTERISTICS
Maximum distance of operation
Voltage max.
Max. current
Operating temperature
According to the standard
24h protection NC circuit (Short wires)
WINDOW
Mount only on wood, aluminium or
un-ferrous made material.
XR200
30V
500mA
+5 ÷ +40°C
CEI 79-2 1° Lev.
NC magnetic contact (Long wires)
10mm
3

Publicidad