INSTRUCTIONS
MODEL:
SL2503/B
Before using or installing the product, kindly read the instructions and follow safety rules. Installation should
be provided by qualified person or company.
Thank you for choosing the item of company PANLUX s.r.o.
Technical data
Power supply: 230V~50Hz
Input fuse: 8A 250VAC
Supply in standby mode: <0,9W
Current: max. 8A
Additional load: max. 1500W (incandescent lamp),
max. 500W (fluorescent lamp)
Protection class: II.
IP Protection: IP66
Angle of detection: horizontal – 360°, vertical – 130°
Reach: max. 6m
Time setting: 10s (±5s) to 4min (±1min), (TIME),
adjustable
Twilight setting: 5-2000lx (LUX), adjustable
Recommended installation height: 2,5m
Terminal block: 3x1,5mm²
Operating temperature: -10°C~50°C
Location: interiors, exteriors
Dimensions: Ø128x45mm
Weight: 220g
Material: plastic ABS
Remarks: relay contact on output
Black(Load)
Blue(Load)
Installation
Blue(Main Power)
Brown(Main Power)
1
2
230V~50Hz
128mm
45mm
Notice
Before using, check the product and make sure there is no damage,
otherwise do not use it.
Before any manipulation assure that mains electrical supply is
disconnected.
In case of damage do not repair or disassemble the product.
For the best functional results, move toward the sensor (see to pic. 5).
The incorrect function of the product can be caused by interruption of
electromagnetic field, small temperature difference between moving
object and surroundings, reflection (e.g. strong luminous source).
Infringement of any mentioned instruction can cause harm to health
or property.
Home Ceiling
L
L
in
out
max 5m
Detection Area
Figure 1
Principle of PIR sensor
PIR sensor receives infra-red waves emitted by objects in reach radius. With movement in the detection area sensor notices
the change and initiates trigger order „Light on" for adjusted time.
Reach setting (sensitivity) – max. 6m
Reach is to be understood as the area traced out by angle of detection and min. to max. available distance from sensor.
Time setting (switch-off delay) – TIME (10s (±5s) to 4min (±1min))
The countdown of adjusted time begins after last detected movement. We recommend setting the function on minimum
during functional test.
Twilight setting (response threshold) – LUX (5–2000lx)
We recommend setting the function on maximum during test.
Stated information may differ according to position and installation height.
Position marked - or  applies to minimum and position marked
If the product is mechanically damaged or connected unprofessionally, guarantee cannot be allowed.
3
4
360°
360˚
130˚
6m
max. 2,5m
max. 3,5m
max 5m
Radius
Figure 2
SL2503
Ceiling PIR sensor 360° | IP66
or
applies to maximum.
+
5
6m
All right reserved.
Technical data can be changed without previous notice.