Descargar Imprimir esta página

EQUATION RFS SL10 Manual De Instrucciones página 14

Kit completo estación + 3 cartuchos incluidos

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 7
INTRODUCTION
This filtration station is placed on the general rain water inlet. Provide the necessary spacings for moun-
ting and replacing the filtering elements. The station fears frost and long exposure to bright light.
Leave a space of at least 10 centimeters below the station for maintenance.
SETUP
It is recommended to install a shut-off valve at the entry and exit of the station.
1 - Screw the valves onto the station after applying sealing tape (Teflon, PTFE) to the threads.
Screw the body of the fittings onto the valves.
2 - Mark the location of the cutout on the water inlet pipe
3 - Shut off the water supply and release the pressure by opening a faucet.
Then close this faucet and cut the tube using the appropriate tool.
4 - Thread the nut then the ring of the fitting on each end of the tube
5 - Temporarily position the station on the tube and mark the location of the bracket fixing screws
6 - Drill the holes
7 - Insert wall plugs suitable for the wall
8 - Fix the bracket to the wall using suitable screws
9 - Tighten the fittings to ensure a seal.
10 - Slowly open the water supply and check that there are no leaks. Retighten fittings if leaks are present.
CARE
The cartridges must be replaced regularly, their lifespan depend on the type of cartridge, the consumption
and quality of the water.
1
• Close the 2 shut-off valves
EN
4
• Place a new cartridge and tighten by
hand (never with the key)
14
2
• Place a bucket, unscrew the bowl with
the key and discard the cartridge
5
• Open the valves and control
there is no leaks
• Retighten fittings if leaks are
present.
3
• Clean the bowl and system cover without
using abrasive cleaning agents.
• Replace the gasket if necessary.
• If the type of cartridge is reusable, then
flush the cartridge.
Spare parts
Description
Reference
Release key
3276007344196
Gasket
3276007344233
Cartridge 1
3276007344417
Cartridge 2
3276007344387
Cartridge 3
3276007344479