Cleaning, Care & Maintenance
1. Before cleaning always disconnect the Multideck Refrigerator from the electricity supply.
2. Clean using either warm soapy water, or a suitable antibacterial cleaning agent, dry thoroughly before
reconnecting the electricity supply.
3. Do not use abrasive or corrosive cleaning agents.
Cleaning the Condenser
Your Polar Multideck Refrigerator will benefit from having the condenser cleaned at regular intervals, your
Polar service agent will be able to carry this out for you.
This unit is fitted with a condensate heater, however if ambient humidity rises above 75%, it may be
necessary to direct the drain line (located at the rear) to a suitable drain outlet or tray.
Condensation and ice will form with frequent and prolonged opening of the doors.
Operating outside of the recommend temperature range and placing next to a heat source
will also increase the amount of ice and internal/external condensation. If external
condensation occurs wipe the surface down with a cloth.
Excessive ice will result in longer running times that will increase energy consumption and
increase the deterioration of components.
If the gasket or seal is damaged or deformed, energy consumption will increase. To restore
efficiency, replace gasket.
Troubleshooting
A qualified technician must carry out repairs if required.
Fault
The appliance is not
working
Poor refrigeration
performance
Showcase is noisy
when turned on
Error code EE4
CD239_ML_A5_v7_20230302.indb 5
CD239_ML_A5_v7_20230302.indb 5
Probable Cause
The unit is not switched on
Plug or lead is damaged
Fuse in the plug has blown
Mains power supply fault
High ambient temperature
Poor ventilation
Too much food in the Showcase is
preventing cold air circulating
Condenser need to be cleaned
Multideck is not level
Multideck is too close to a wall or
other object
Restricted Airflow
Blocked Condenser
Solution
Check the unit is plugged in correctly and
switched on
Replace Plug or lead
Replace the fuse
Check mains power supply
Ventilate room or area around Multideck
Increase air flow around Multideck
Take out some food
Consult a qualified Technician
Adjust position to level
Move position
Increase airflow
Consult a qualified Technician