Care and Cleaning
□
To clean, wipe down with a damp cloth and dry with a towel.
□
Do not use abrasive cleaners, steel wool, or harsh chemicals when cleaning this faucet, or the warranty will
be voided.
Troubleshooting
NOTE: Refer to the service parts section in this manual for
a detailed drawing showing the location of the parts listed
below.
Problem
There are leaks from the
handle.
The aerator has an
irregular or reduced
water ow.
The water will not shut off
completely.
Reinstalling the cartridges:
Possible Cause
The bonnet nut has come loose and/or the
washer is dirty or damaged.
The aerator is dirty or mis- tted.
The rubber seat and spring under the handle
cartridge is dirty or broken.
2
1
□
□
□
□
□
□
□
□
2
1
Fig. 1
7
Please contact 1-855-HD-GLACIER for further assistance.
Solution
Tighten the bonnet nut.
Clean or replace the washer.
Remove the aerator and
check for debris.
Ensure that the rubber washer
is properly installed.
Remove the handle.
Remove the cartridge to check
the rubber seat and spring.
Clean or replace.
When reinstalling the cartridges,
make sure the rubber seats and
springs (1) are below the
cartridge (2). The spring should
be installed rst into the slot
and then the rubber seat. The
cartridge should then be installed
with the molded stops (a & b)
facing inward as shown in Fig. 1.
a
HOMEDEPOT.COM/GLACIERBAY
b