Electrical Settings
WARNING: Disconnect power before working on the pump, motor, pressure switch, or wiring.
CAUTION: The motor may be hot. Allow the motor to cool for 20 minutes after shut down.
CAUTION: Water pressure may have built up in the pump, pipes, or tank. Drain water to relieve pressure.
MOTOR VOLTAGE SETTINGS
Motors are designed to run on either 115 volt or 230 volt power.
Ensure the motor's voltage is set to match the voltage being
supplied to your motor from the electrical source.
To set your motor to the correct voltage, first remove
the rear motor cover plate. Next slide the voltage
conversion switch to the correct voltage.
Motor Cover
Screws
Wiring Connections
WARNING: Risk of electric shock. Can shock, burn, or kill.
1.
To avoid dangerous or fatal electrical shock, turn OFF power to the motor before working on electrical
connections.
2.
Ground the motor before connecting to electrical power supply. Failure to ground the motor can cause severe or
fatal electrical shock hazard.
3.
Supply voltage must be within +/- 10% of the nameplate voltage. Incorrect voltage can cause fire or damage the
motor and voids the warranty. If in doubt consult a licensed electrician.
4.
Use a wire size specified in the Wiring Chart (below). If possible, connect the pump to a separate branch circuit
with no other appliances on it.
5.
Do not ground to a gas supply line.
6.
Set the motor according to the
7.
If the diagram on the motor cover plate differs fr om the diagrams in this section, follow the diagram on the
motor cover plate.
8.
If this procedure or the wiring diagrams are confusing, consult a licensed electrician.
RECOMMENDED WIRE AND FUSE SIZES FOR 115 AND 230 VOLTS
MAX. LOAD
MOTOR HP
VOLTS
1-1/2
115/230 20.09/10.05
diagram on the motor cover plate.
BRANCH FUSE
AWG MIN. WIRE
AMP
RATING AMP
SIZE (mm
30/15
10/14 (5.5/2)
HOT
L1
115
L2
To Breaker
Neutral
To Breaker
Set for 115V
DISTANCE IN FEET FROM MOTOR TO SUPPLY
0-100
101-200
2
)
10/14 (5.5/2)
8/14 (8.4/2)
7
Please contact 1-844-883-1872 for further assistance.
L1
230
L2
Set for 230V
201-300
301-400
AWG WIRE SIZE (mm
2
)
6/12 (14/3) 4/10 (21/5.5) 4/10 (21/5.5)
HOT
To Breaker
HOT
To Breaker
401-500
HOMEDEPOT.COM