9. Specifi cations
The most important specifi cations are shown on the data plates on the
Combifoamer and pump, respectively.
Combifoamer
Water
Max. work pressure (bar)
Pump pressure (bar)
Min. water supply (l/min)
Supply pressure (bar)
o
Max. temperature (
C)
Air
Supply (bar)
Consumption (l/min.)
Electricity
Voltage
Power consumption (KW)
Motor guard, setting (A)
Fuses (A)
Weight (kg)
Dimensions (H x W x D)
Sound pressure level L
measured according to ISO 11202 [DISTANCE 1 m] [FULL LOAD]:
pA
Under 70 dB(A).
22
S410
S417
14 -16
19 - 21
12
100
2 - 4
2 - 4
70
5 - 10
5 - 10
200
200
3x400V/50Hz
3x400V/50Hz
2,2
2,2
4,75
4,75
10
110
110
1010x600x310
1010x600x310
S420
23 - 25
17
21
50
50
2 - 4
70
70
5- 10
200
3x400V/50Hz
2,2
4,75
10
10
110
1010x600x310